  • Lekholm, Ville,1976-Uppsala universitet,Mikrosystemteknik,ÅSTC (författare)

Investigation of a zirconia co-fired ceramic calorimetric microsensor for high-temperature flow measurements

  • Artikel/kapitelEngelska2015

Förlag, utgivningsår, omfång ...

  • 2015-05-19
  • IOP Publishing,2015
  • printrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:uu-246059
  • https://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-246059URI
  • https://doi.org/10.1088/0960-1317/25/6/065014DOI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • This paper describes the design, fabrication and characterization of a flow sensor for high-temperature, or otherwise aggressive, environments, like, e.g. the propulsion system of a small spacecraft. The sensor was fabricated using 8 mol% yttria stabilized zirconia (YSZ8) high-temperature co-fired ceramic (HTCC) tape and screen printed platinum paste. A calorimetric flow sensor design was used, with five 80 mu m wide conductors, separated by 160 mu m, in a 0.4 mm wide, 0.1 mm deep and 12.5 mm long flow channel. The central conductor was used as a heater for the sensor, and the two adjacent conductors were used to resistively measure the heat transferred from the heater by forced convection. The two outermost conductors were used to study the influence of an auxiliary heat source on the sensor. The resistances of the sensor conductors were measured using four-point connections, as the gas flow rate was slowly increased from 0 to 40 sccm, with different power supplied through the central heater, as well as with an upstream or downstream heater powered. In this study, the thermal and electrical integrability of microcomponents on the YSZ8 substrate was of particular interest and, hence, the influence of thermal and ionic conduction in the substrate was studied in detail. The effect of the ion conductivity of YSZ8 was studied by measuring the resistance of a platinum conductor and the resistance between two adjacent conductors on YSZ8, in a furnace at temperatures from 20 to 930 degrees C and by measuring the resistance with increasing current through a conductor. With this design, the influence of ion conductivity through the substrate became apparent above 700 degrees C. The sensitivity of the sensor was up to 1 m Omega sccm(-1) in a range of 0-10 sccm. The results show that the signal from the sensor is influenced by the integrated auxiliary heating conductors and that these auxiliary heaters provide a way to balance disturbing heat sources, e.g. thrusters or other electronics, in conjunction with the flow sensor.

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Persson, AndersUppsala universitet,Mikrosystemteknik(Swepub:uu)andpe782 (författare)
  • Klintberg, LenaUppsala universitet,Mikrosystemteknik(Swepub:uu)lkl28025 (författare)
  • Thornell, GregerUppsala universitet,Mikrosystemteknik,ÅSTC(Swepub:uu)gth12095 (författare)
  • Uppsala universitetMikrosystemteknik (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Journal of Micromechanics and Microengineering: IOP Publishing25:60960-13171361-6439

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Lekholm, Ville, ...
Persson, Anders
Klintberg, Lena
Thornell, Greger
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Annan teknik
Artiklar i publikationen
Journal of Micro ...
Av lärosätet
Uppsala universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy