SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Thor Andreas)
 

Sökning: WFRF:(Thor Andreas) > (2015-2019) > Comparison analysis...

Comparison analysis of orbital shape and volume in unilateral fractured orbits

Nilsson, Johanna (författare)
Uppsala universitet,Käkkirurgi,Department of Oral & Maxillofacial Surgery, Zealand University Hospital, Køge, Denmark
Nysjö, Johan (författare)
Uppsala universitet,Avdelningen för visuell information och interaktion,Bildanalys och människa-datorinteraktion
Carlsson, Anders-Petter (författare)
Uppsala universitet,Käkkirurgi,Department of Oral & Maxillofacial Surgery, Zealand University Hospital, Køge, Denmark
visa fler...
Thor, Andreas (författare)
Uppsala universitet,Käkkirurgi
visa färre...
 (creator_code:org_t)
Elsevier BV, 2018
2018
Engelska.
Ingår i: Journal of Cranio-Maxillofacial Surgery. - : Elsevier BV. - 1010-5182 .- 1878-4119. ; 46:3, s. 381-387
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Facial fractures often result in changes of the orbital volume. These changes can be measured in three-dimensional (3D) computed tomography (CT) scans for preoperative planning and postoperative evaluation. The aim of this study was to analyze the orbital volume and shape before and after surgical treatment of unilateral orbital fractures using semi-automatic image segmentation and registration techniques. The orbital volume in 21 patients was assessed by a semi-automatic model-based segmentation method. The fractured orbit was compared relative to the contralateral orbit. The same procedure was performed for the postoperative evaluation. Two observers performed the segmentation procedure, and the inter- and intraobserver variability was evaluated. The interobserver variability (mean volume difference ± 1.96 SD) was −0.6 ± 1.0 ml in the first trial and 0.7 ± 0.8 ml in the second trial. The intra-observer variability was −0.2 ± 0.7 ml for the first observer and 1.1 ± 0.9 ml for the second observer. The average volume overlap (Dice similarity coefficient) between the fractured and contralateral side increased after surgery, while the mean and maximum surface distance decreased, indicating that the surgery contributed to a re-establishment of size and shape. In conclusion, our study shows that the semi-automatic segmentation method has precision for detecting volume differences down to 1.0 ml. The combination of semi-automatic segmentation and 3D shape analysis provides a powerful tool for planning and evaluating treatment of orbital fractures.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kirurgi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Surgery (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk bildbehandling (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Image Processing (hsv//eng)

Nyckelord

Computerized Image Processing
Datoriserad bildbehandling

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Nilsson, Johanna
Nysjö, Johan
Carlsson, Anders ...
Thor, Andreas
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Kirurgi
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Medicinteknik
och Medicinsk bildbe ...
Artiklar i publikationen
Journal of Crani ...
Av lärosätet
Uppsala universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy