SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Stenberg Jenny 1976 )
 

Sökning: WFRF:(Stenberg Jenny 1976 ) > Clinical praxis for...

Clinical praxis for assessment of dry weight in Sweden and Denmark : A mixed-methods study

Stenberg, Jenny, 1976- (författare)
Uppsala universitet,Njurmedicin,Department of Medical Sciences, University Hospital, Uppsala, Sweden
Lindberg, Magnus (författare)
Högskolan i Gävle,Uppsala universitet,Vårdvetenskap,Medicin- och vårdvetenskap,Department of Public Health and Caring Sciences, Uppsala University, Uppsala, Sweden
Furuland, Hans (författare)
Uppsala universitet,Njurmedicin,Department of Medical Sciences, University Hospital, Uppsala, Sweden
 (creator_code:org_t)
2015-08-11
2016
Engelska.
Ingår i: Hemodialysis International. - : Wiley. - 1492-7535 .- 1542-4758. ; 20:1, s. 111-119
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Overhydration is an independent predictor of mortality in hemodialysis (HD) patients. More than 30% of HD patients are overhydrated, motivating the development of new methods for assessing hydration status. This study surveyed clinical praxis and local guidelines for dry weight (DW) assessment in Swedish and Danish HD units, and examined if differences in routines and utilization of bioimpedance spectroscopy (BIS) and other assistive technology affected frequency of DW adjustments and blood pressure (BP) levels. Cross-sectional information on praxis, guidelines and routines, plus treatment-related data from 99 stratified patients were collected. Qualitative data were analyzed with content analysis and interpreted in convergence with statistical analysis of quantitative data in a mixed-methods design. Local guidelines concerning DW existed in 54% of the units. A BIS device was present in 52%, but only half of those units used it regularly, and no correlations to frequency of DW adjustments or BP were found. HD nurses were authorized to adjust DW in 60% of the units; in these units, the frequency of DW adjustments was 1.6 times higher and systolic BP pre-HD 8 mmHg lower. There is a wide variation in routines for DW determination, and there are indications that authorization of HD nurses to adjust DW may improve DW assessment. BIS is sparsely used; its implementation may have been delayed by uncertainty over how to manage the device and interpret measurements. Hence, better methods and guidelines for assessing DW and using BIS need to be developed.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Urologi och njurmedicin (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Urology and Nephrology (hsv//eng)

Nyckelord

Hemodialysis
dry weight
bioimpedance spectroscopy
guidelines
blood pressure
mixed-methods design
Medicinsk vetenskap
Medical Science

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Stenberg, Jenny, ...
Lindberg, Magnus
Furuland, Hans
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Urologi och njur ...
Artiklar i publikationen
Hemodialysis Int ...
Av lärosätet
Uppsala universitet
Högskolan i Gävle

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy