SwePub
Sök i LIBRIS databas

  Utökad sökning

L773:0090 6964 OR L773:1573 9686
 

Sökning: L773:0090 6964 OR L773:1573 9686 > (2015-2019) > Surface and Subsurf...

Surface and Subsurface Analyses of Metal-on-Polyethylene Total Hip Replacement Retrievals

Vuong, Vicky (författare)
Department of Materials Science and Engineering, McMaster University, 1280 Main Street West, Hamilton, ON, L8S 4L8, Canada
Pettersson, Maria (författare)
Uppsala universitet,Tillämpad materialvetenskap
Persson, Cecilia (författare)
Uppsala universitet,Tillämpad materialvetenskap,Materials in Medicine
visa fler...
Larsson, Sune (författare)
Uppsala universitet,Ortopedi
Grandfield, Kathryn (författare)
Department of Materials Science and Engineering, McMaster University, 1280 Main Street West, Hamilton, ON, L8S 4L8, Canada
Engqvist, Håkan (författare)
Uppsala universitet,Tillämpad materialvetenskap,Materials in Medicine
visa färre...
 (creator_code:org_t)
2015-09-23
2016
Engelska.
Ingår i: Annals of Biomedical Engineering. - : Springer Nature. - 0090-6964 .- 1573-9686. ; 44:5, s. 1685-1697
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Metal-on-polyethylene (MoP) articulations are one of the most reliable implanted hip prostheses. Unfortunately, long-term failure remains an obstacle to the service life. There is a lack of higher resolution research investigating the metallic surface component of MoP hip implants. This study investigates the surface and subsurface features of metallic cobalt chromium molybdenum alloy (CoCrMo) femoral head components from failed MoP retrievals. Unused prostheses were used for comparison to differentiate between wear-induced defects and imperfections incurred during implant manufacturing. The predominant scratch morphology observed on the non-implanted references was shallow and linear, whereas the scratches on the retrievals consisted of largely nonlinear, irregular scratches of varying depth (up to 150 nm in retrievals and up to 60 nm in reference samples). Characteristic hard phases were observed on the surface and subsurface material of the cast samples. Across all samples, a 100-400 nm thick nanocrystalline layer was visible in the immediate subsurface microstructure. Although observation of the nanocrystalline layer has been reported in metal-on-metal articulations, its presence in MoP retrievals and unimplanted prostheses has not been extensively examined. The results suggest that manufacturing-induced surface and subsurface microstructural features are present in MoP hip prostheses prior to implantation and naturally, these imperfections may influence the in vivo wear processes after implantation.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Medicinsk bioteknologi -- Biomaterialvetenskap (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Medical Biotechnology -- Biomaterials Science (hsv//eng)

Nyckelord

Hip implant retrievals
Cobalt chromium
Metalon-polymer
Transmission electron microscopy
Biotribology
Electron microscopy

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy