The HemoScreen, a novel haematology analyser for the point of care

Ben-Yosef, Yaara (författare)
PixCell Med Technol Ltd, Yokneam Ilit, Israel
Marom, Barak (författare)
PixCell Med Technol Ltd, Yokneam Ilit, Israel
Hirshberg, Galit (författare)
PixCell Med Technol Ltd, Yokneam Ilit, Israel
visa fler...
D'Souza, Carol (författare)
Univ Westminster, Fac Sci & Technol, Biomed Sci, London, England
Larsson, Anders (författare)
Uppsala universitet,Biokemisk struktur och funktion
Bransky, Avishay (författare)
PixCell Med Technol Ltd, Yokneam Ilit, Israel
visa färre...
 (creator_code:org_t)
2016-01-19
2016
Engelska.
Ingår i: Journal of Clinical Pathology. - : BMJ. - 0021-9746 .- 1472-4146. ; 69:8, s. 720-725
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • BACKGROUND AND AIMS: A haematology analyser, based on a new technology, is presented herein. The analyser that provides a complete blood count (CBC) and five-part differential accepts disposable cartridges containing all required reagents, making it maintenance-free and ideal for point-of-care (POC) settings. The test reproducibility and imperviousness to analytical errors are attributed to the imaging-based analysis employed. Imaging enables cell-morphology-based differentiation, which is analogous to the gold standard microscopic analysis. This article presents the HemoScreen new technology and evaluates its performance through a small-scale study conducted in its designated clinical settings.METHODS: Thirty anticoagulated whole blood samples were analysed on the HemoScreen and Sysmex XE-2100. Linear regression was performed for the methods comparison. Two samples with 15 replicates were processed for imprecision. Ease of use of the device was also considered.RESULTS: The HemoScreen demonstrated acceptable imprecision and good agreement with the Sysmex XE-2100. The white blood cells (WBCs), red blood cells (RBCs), haemoglobin (HGB), haematocrit (HCT), platelets (PLT), neutrophils, lymphocytes and eosinophils have coefficients of correlation (r) >0.97. For mean cell volume (MCV), mean cell HGB (MCH) and RBC distribution width (RDW), r values ranged from 0.92 to 0.96. For mean cell HGB concentration (MCHC) and monocytes r=0.82 was demonstrated. User-friendliness and suitability of the device for operation in the designated POC settings was also confirmed.CONCLUSIONS: The HemoScreen employs innovative technologies of viscoelastic focusing and microfluidics within a disposable cartridge for an image-based blood cell analysis. By providing accurate and repeatable CBC and five-part differential results within minutes and maintaining the simplicity of operation, the HemoScreen could have far-reaching implications for use at POC. Further extended evaluation is in progress.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Hematologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Hematology (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy