SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Sturesson Peter 1981 )
 

Sökning: WFRF:(Sturesson Peter 1981 ) > Ceramic Pressure Se...

Ceramic Pressure Sensor for High Temperatures – Investigation of the Effect of Metallizationon on Read Range

Sturesson, Peter, 1981- (författare)
Försvarshögskolan,Uppsala universitet,Mikrosystemteknik,Swedish Def Univ, Dept Mil Sci, S-11428 Stockholm, Sweden.,Ångström Space Technology Centre (ÅSTC), Ångström Space Technology Centre (ÅSTC),Sektionen för militärtekniska system (MteS),Uppsala Univ, Dept Engn Sci, Angstrom Space Technol Ctr, Sweden; Uppsala Univ, Dept Engn Sci, Div Microsyst Technol, Sweden
Khaji, Zahra (författare)
Uppsala universitet,Mikrosystemteknik,Uppsala Univ, Dept Engn Sci, Div Microsyst Technol, Sweden,ÅSTC
Klintberg, Lena (författare)
Uppsala universitet,Mikrosystemteknik,Uppsala Univ, Dept Engn Sci, Div Microsyst Technol, Sweden,MST
visa fler...
Thornell, Greger, 1969- (författare)
Uppsala universitet,Mikrosystemteknik,Ångström Space Technology Centre (ÅSTC), Ångström Space Technology Centre (ÅSTC),Uppsala Univ, Dept Engn Sci, Angstrom Space Technol Ctr, Sweden; Uppsala Univ, Dept Engn Sci, Div Microsyst Technol, Sweden
visa färre...
 (creator_code:org_t)
2017
2017
Engelska.
Ingår i: IEEE Sensors Journal. - 1530-437X .- 1558-1748. ; 17:8, s. 2411-2421
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • A study on the relationship between circuit metallization, made by double-layer screen printing of platinum and electroplating of silver on top of platinum, and its impact on practical read range of ceramic LC resonators for high-temperature pressure measurements is presented. Also included is the first realization of membranes by draping a graphite insert with ceramic green body sheets. As a quality factor circuit reference, two-port microstrip meander devices were positively evaluated and to study interdiffusion between silver and platinum, test samples were annealed at 500 degrees C, 700 degrees C, and 900 degrees C for 4, 36, 72, and 96 h. The LC resonators were fabricated with both metallization methods, and the practical read range at room temperature was evaluated. Pressure-sensitive membranes were characterized for pressures up to 2.5 bar at room temperature, 500 degrees C and up to 900 degrees C. Samples electroplated with silver exhibited performance equal to or better than double-layer platinum samples for up to 60 h at 500 degrees C, 20 h at 700 degrees C, and for 1 h at 900 degrees C, which was correlated with the degree of interdiffusion as determined from cross-sectional analysis. The LC resonator samples with double-layer platinum exhibited a read range of 61 mm, and the samples with platinum and silver exhibited a read range of 59 mm. The lowest sheet resistance, and, thereby, the highest read range of 86 mm, was obtained with a silver electroplated LC resonator sample after 36 h of annealing at 500 degrees C.

Ämnesord

NATURVETENSKAP  -- Fysik -- Acceleratorfysik och instrumentering (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences -- Accelerator Physics and Instrumentation (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Maskinteknik -- Rymd- och flygteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Mechanical Engineering -- Aerospace Engineering (hsv//eng)

Nyckelord

Alternative metallization
ceramic membrane
harsh environment sensor
high temperature co-fired ceramics (HTCC)
HTCC processing
LC resonator
pressure sensor
wireless reading
Teknisk fysik med inriktning mot mikrosystemteknik
Engineering Science with specialization in Microsystems Technology
Försvarssystem

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy