SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:uu-304881"
 

Sökning: id:"swepub:oai:DiVA.org:uu-304881" > Energy expenditure ...

  • Ekelund, Ulf,1960-Unit for Preventive Nutrition at Novum, Department of Medical Nutrition/Biosciences, Karolinska Institutet, Stockholm, Sweden; Department of Physical Education and Health, Örebro University, Sweden (författare)

Energy expenditure assessed by heart rate and doubly labeled water in young athletes

  • Artikel/kapitelEngelska2002

Förlag, utgivningsår, omfång ...

  • Ovid Technologies (Wolters Kluwer Health),2002
  • printrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:uu-304881
  • https://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-304881URI
  • https://doi.org/10.1097/00005768-200208000-00019DOI
  • https://urn.kb.se/resolve?urn=urn:nbn:se:oru:diva-30481URI
  • http://kipublications.ki.se/Default.aspx?queryparsed=id:1939662URI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • PURPOSE: To compare total energy expenditure (TEE) estimated by the FLEX heart rate (HR) method with that measured by the doubly labeled water (DLW) technique in young speed skaters. We hypothesized that the accuracy of FLEX HR-estimated TEE would be affected by a) the definition of the FLEX HR and b) the type of training regimen.METHODS: Eight young athletes (mean age 18.2 +/- 1.3 yr) underwent measurements during two 10-d training periods: an off-season period with voluntary training (predominantly running) and a preseason period mainly focused on skating technique training. TEE was measured simultaneously by the DLW and FLEX HR methods. FLEX HR1 was defined as the mean of the HRs during all resting calibration activities and the lowest HR during exercising calibration activities. FLEX HR2 was defined as the mean of the highest HR during resting activities and the lowest HR during exercising.RESULTS: ANOVA showed that FLEX HR1 was significantly lower than FLEX HR2 (mean of both periods; 77 +/- 5 vs 84 +/- 6 beats.min(-1); P = 0.004). TEE values obtained by DLW were 16.8 +/- 3.8 and 16.9 +/- 2.9 MJ.d(-1) in the two periods, respectively. TEE values calculated from FLEX HR1 were 17.8 +/- 3.6 and 17.4 +/- 2.6 MJ.d(-1), and those from FLEX HR2 17.1 +/- 3.1 and 17.0 +/- 2.7 MJ.d-1, respectively. No significant period (P = 0.83) or method (P = 0.44) effect on TEE was observed.CONCLUSION: FLEX HR-estimated TEE was not affected by the definition of the FLEX HR or by the type of training regimen as compared with TEE measured by the DLW method in young athletes.

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Yngve, Agneta,Professor,1953-Karolinska Institutet(Swepub:oru)aye (författare)
  • Westerterp, KlaasDepartment of Human Biology, Maastricht University, Maastricht, The Netherlands (författare)
  • Sjöström, MichaelKarolinska Institutet (författare)
  • Karolinska InstitutetUnit for Preventive Nutrition at Novum, Department of Medical Nutrition/Biosciences, Karolinska Institutet, Stockholm, Sweden; Department of Physical Education and Health, Örebro University, Sweden (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Medicine & Science in Sports & Exercise: Ovid Technologies (Wolters Kluwer Health)34:8, s. 1360-13660195-91311530-0315

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy