SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:uu-316340"
 

Sökning: id:"swepub:oai:DiVA.org:uu-316340" > Time-Frequency Anal...

  • Gunasekara, T. A. L. N.Univ Colombo, Dept Phys, Colombo, Sri Lanka. (författare)

Time-Frequency Analysis of Narrow Bipolar Pulses observed in Sri Lanka

  • Artikel/kapitelEngelska2016

Förlag, utgivningsår, omfång ...

  • 2016
  • printrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:uu-316340
  • https://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-316340URI
  • https://doi.org/10.1109/ICLP.2016.7791401DOI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:kon swepub-publicationtype

Anmärkningar

  • Narrow Bipolar Pulses (NBP) of a single thunderstorm from a coastal location in Sri Lanka were subjected to S-transformation in order to study their time frequency information. This study is an extension to a similar study carried out by the authors where properties of NBPs were analyzed using the wavelet transformation. Keeping in line with the previous study, 18 events pertaining to equal number of positive and negative NBPs with the narrowest temporal widths were studied. The data was obtained from the southern coastal area of Sri Lanka (Matara - 5.95 degrees N, 8.53 degrees E) from a highly active thunderstorm, which occurred during the month of May in 2013. The waveforms were recorded with a 10 ns resolution within a 100 ms time window. The spanning (width) and the ratio of peak power amongst the initial and overshoot pulses were measured and compared for each polarity. The negative NBPs had an average spanning of 134 - 371 kHz. The overshoot of the same had an average range of 127 - 255 kHz. The positive NBPs had an average spanning of 103 - 245 kHz. The overshoot of the same had an average range of 102 - 195 kHz. The ratio of peak power of NBPs to overshoot had an average of 1.08 for both positive and negative pulses. The spectrogram reveals the initial and overshoots pulses to be relatively equal in power intensities.

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Vayanganie, S. P. A.Univ Colombo, Dept Phys, Colombo, Sri Lanka. (författare)
  • Jayalal, S. N.Univ Colombo, Dept Phys, Colombo, Sri Lanka. (författare)
  • Fernando, M.Univ Colombo, Dept Phys, Colombo, Sri Lanka. (författare)
  • Sonnadara, D. U. J.Univ Colombo, Dept Phys, Colombo, Sri Lanka. (författare)
  • Cooray, Vernon,1952-Uppsala universitet,Elektricitetslära(Swepub:uu)verncoor (författare)
  • Univ Colombo, Dept Phys, Colombo, Sri Lanka.Elektricitetslära (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:2016 33RD INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP)9781509058433

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy