SwePub
Sök i LIBRIS databas

  Utökad sökning

(WFRF:(Hedin Eva Maria))
 

Sökning: (WFRF:(Hedin Eva Maria)) > Case Studies in Phy...

Case Studies in Physiology : Ventilation and perfusion in a giraffe-does size matter?

Nyman, Görel (författare)
Swedish University of Agricultural Sciences,Sveriges lantbruksuniversitet,Institutionen för kliniska vetenskaper (KV),Department of Clinical Sciences
Röken, Bengt (författare)
Kolmarden Wild Anim Pk, Kolmarden, Sweden.
Hedin, Eva-Maria (författare)
Uppsala universitet,Kardiologi-arrytmi
visa fler...
Hedenstierna, Göran (författare)
Uppsala universitet,Hedenstiernalaboratoriet,Klinisk fysiologi
visa färre...
 (creator_code:org_t)
 
American Physiological Society, 2016
2016
Engelska.
Ingår i: Journal of applied physiology. - : American Physiological Society. - 8750-7587 .- 1522-1601. ; 121:6, s. 1374-1378
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The trachea in the giraffe is long but narrow, and dead space ventilation is considered to be of approximately the same size as in other mammals. Less is known about the matching between ventilation and lung blood flow. The lungs in the giraffe are large, up to 1 m high and 0.7 m wide, and this may cause considerable ventilation/perfusion (V-A/Q) mismatch due to the influence of gravitational forces, which could lead to hypoxemia. We studied a young giraffe under anesthesia using the multiple inert gas elimination technique to analyze the V-A/Q distribution and arterial oxygenation and compared the results with those obtained in other species of different sizes, including humans. V-A/Q distribution was broad but unimodal, and the shunt of blood flow through nonventilated lung regions was essentially absent, suggesting no lung collapse. The V-A/Q match was as good as in the similarly sized horse and was even comparable to that in smaller sized animals, including rabbit and rat. The match was also similar to that in anesthetized humans. Arterial oxygenation was essentially similar in all studied species. The findings suggest that the efficiency of V-A/Q matching is independent of lung size in the studied mammals that vary in weight from less than 1 to more than 400 kg.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Hälsovetenskap -- Sjukgymnastik (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Health Sciences -- Physiotherapy (hsv//eng)
LANTBRUKSVETENSKAPER  -- Veterinärmedicin -- Klinisk vetenskap (hsv//swe)
AGRICULTURAL SCIENCES  -- Veterinary Science -- Clinical Science (hsv//eng)

Nyckelord

giraffe
ventilation
gas exchange
ventilation/perfusion

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy