SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Kuentz Martin)
 

Sökning: WFRF:(Kuentz Martin) > Flow-through cross-...

Flow-through cross-polarized imaging as a new tool to overcome the analytical sensitivity challenges of a low-dose crystalline compound in a lipid matrix

Adler, Camille (författare)
Univ Appl Sci & Arts Northwestern Switzerland, Inst Pharmaceut Technol, CH-4132 Muttenz, Switzerland.;Univ Basel, Inst Pharmaceut Technol, CH-4056 Basel, Switzerland.
Schoenenberger, Monica (författare)
Swiss Nanosci Inst, Nanotech Serv Lab, CH-4056 Basel, Switzerland.
Teleki, Alexandra (författare)
DSM Nutr Prod Ltd, Res Ctr Formulat & Applicat, CH-4002 Basel, Switzerland.
visa fler...
Leuenberger, Bruno (författare)
DSM Nutr Prod Ltd, Res Ctr Formulat & Applicat, CH-4002 Basel, Switzerland.
Kuentz, Martin (författare)
Univ Appl Sci & Arts Northwestern Switzerland, Inst Pharmaceut Technol, CH-4132 Muttenz, Switzerland.
visa färre...
Univ Appl Sci & Arts Northwestern Switzerland, Inst Pharmaceut Technol, CH-4132 Muttenz, Switzerland;Univ Basel, Inst Pharmaceut Technol, CH-4056 Basel, Switzerland. Swiss Nanosci Inst, Nanotech Serv Lab, CH-4056 Basel, Switzerland. (creator_code:org_t)
Elsevier BV, 2015
2015
Engelska.
Ingår i: Journal of Pharmaceutical and Biomedical Analysis. - : Elsevier BV. - 0731-7085 .- 1873-264X. ; 115, s. 20-30
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Assessing the physical state of a low-dose active compound in a solid lipid or polymer matrix is analytically challenging, especially if the matrix exhibits some crystallinity. The aim of this study was first to compare the ability of current methods to detect the presence of a crystalline model compound in lipid matrices. Subsequently, a new technique was introduced and evaluated because of sensitivity issues that were encountered with current methods. The new technique is a flow-through version of cross-polarized imaging in transmission mode. The tested lipid-based solid dispersions (SDs) consisted of beta-carotene (BC) as a model compound, and of Gelucire 50/13 or Geleol mono- and diglycerides as lipid matrices. The solid dispersions were analyzed by (hyper) differential scanning calorimetry (DSC), X-ray powder diffraction (XRPD), and microscopic techniques including atomic force microscopy (AFM). DSC and XRPD could analyze crystalline BC at concentrations as low as 3% (w/w) in the formulations. However, with microscopic techniques crystalline particles were detected at significantly lower concentrations of even 0.5% (w/w) BC. A flow-through cross-polarized imaging technique was introduced that combines the advantage of analyzing a larger sample size with high sensitivity of microscopy. Crystals were detected easily in samples containing even less than 0.2% (w/w) BC. Moreover, the new tool enabled approximation of the kinetic BC solubility in the crystalline lipid matrices. As a conclusion, the flow-through cross-polarized imaging technique has the potential to become an indispensable tool for characterizing low-dose crystalline compounds in a lipid or polymer matrix of solid dispersions. (C) 2015 Elsevier B.V. All rights reserved.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Medicinska och farmaceutiska grundvetenskaper -- Läkemedelskemi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Basic Medicine -- Medicinal Chemistry (hsv//eng)

Nyckelord

Solid lipid formulations
Crystalline active compound
Analytical tools
Sensitivity limits
Sampling issues
Flow-through cross-polarized imaging

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy