SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Källback Patrik)
 

Sökning: WFRF:(Källback Patrik) > A Space Efficient D...

A Space Efficient Direct Access Data Compression Approach for Mass Spectrometry Imaging

Källback, Patrik (författare)
Uppsala universitet,Institutionen för farmaceutisk biovetenskap,Science for Life Laboratory, SciLifeLab,Biomolecular Mass Spectrometry Imaging
Nilsson, Anna (författare)
Uppsala universitet,Institutionen för farmaceutisk biovetenskap,Science for Life Laboratory, SciLifeLab,Biomolecular Mass Spectrometry Imaging
Andrén, Per E. (författare)
Uppsala universitet,Institutionen för farmaceutisk biovetenskap,Science for Life Laboratory, SciLifeLab,Biomolecular Mass Spectrometry Imaging
 (creator_code:org_t)
2018-02-23
2018
Engelska.
Ingår i: Analytical Chemistry. - : American Chemical Society (ACS). - 0003-2700 .- 1520-6882. ; 90:6, s. 3676-3682
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Advances in mass spectrometry imaging that improve both spatial and mass resolution are resulting in increasingly larger data files that are difficult to handle with current software. We have developed a novel near-lossless compression method with data entropy reduction that reduces the file size significantly. The reduction in data size can be set at four different levels (coarse, medium, fine, and superfine) prior to running the data compression. This can be applied to spectra or spectrum-by-spectrum, or it can be applied to transpose arrays or array-by-array, to efficiently read the data without decompressing the whole data set. The results show that a compression ratio of up to 5.9:1 was achieved for data from commercial mass spectrometry software programs and 55:1 for data from our in-house developed mslQuant program. Comparing the average signals from regions of interest, the maximum deviation was 0.2% between compressed and uncompressed data sets with coarse accuracy for the data entropy reduction. In addition, when accessing the compressed data by selecting a random m/z value using mslQuant, the time to update an image on the computer screen was only slightly increased from 92 (+/- 32) ms (uncompressed) to 114 (+/- 13) ms (compressed). Furthermore, the compressed data can be stored on readily accessible servers for data evaluation without further data reprocessing. We have developed a space efficient, direct access data compression algorithm for mass spectrometry imaging, which can be used for various data-demanding mass spectrometry imaging applications.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Medicinska och farmaceutiska grundvetenskaper -- Farmaceutiska vetenskaper (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Basic Medicine -- Pharmaceutical Sciences (hsv//eng)
NATURVETENSKAP  -- Kemi -- Analytisk kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences -- Analytical Chemistry (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Källback, Patrik
Nilsson, Anna
Andrén, Per E.
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Medicinska och f ...
och Farmaceutiska ve ...
NATURVETENSKAP
NATURVETENSKAP
och Kemi
och Analytisk kemi
Artiklar i publikationen
Analytical Chemi ...
Av lärosätet
Uppsala universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy