Comparison of metal ion concentrations and implant survival after total hip arthroplasty with metal-on-metal versus metal-on-polyethylene articulations : a 16-year follow-up of a prospective randomized study

Dahlstrand, Henrik (författare)
Karolinska Univ Hosp, Karolinska Inst, Sect Orthopaed & Sports Med, Dept Mol Med & Surg, Stockholm, Sweden.
Stark, Andre (författare)
Karolinska Inst, Danderyd Hosp, Dept Clin Sci, Stockholm, Sweden.
Wick, Marius C. (författare)
Karolinska Univ Hosp, Karolinska Inst Stockholm, Funct Unit Musculoskeletal Radiol Funct Imaging &, Stockholm, Sweden.
visa fler...
Anissian, Lucas (författare)
Oregon Hlth & Sci Univ, Dept Orthopaed Surg, Portland, OR USA.
Hailer, Nils (författare)
Uppsala universitet,Ortopedi
Weiss, Rudiger J. (författare)
Karolinska Univ Hosp, Karolinska Inst, Sect Orthopaed & Sports Med, Dept Mol Med & Surg, Stockholm, Sweden.
visa färre...
Karolinska Univ Hosp, Karolinska Inst, Sect Orthopaed & Sports Med, Dept Mol Med & Surg, Stockholm, Sweden Karolinska Inst, Danderyd Hosp, Dept Clin Sci, Stockholm, Sweden. (creator_code:org_t)
2017-07-12
2017
Engelska.
Ingår i: Acta Orthopaedica. - : Medical Journals Sweden AB. - 1745-3674 .- 1745-3682. ; 88:5, s. 490-495
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background and purpose - Large metal-on-metal (MoM) articulations are associated with metal wear and corrosion, leading to increased metal ion concentrations and unacceptable revision rates. There are few comparative studies of 28-mm MoM articulations with conventional metal-on-polyethylene (MoP) couplings. We present a long-term follow-up of a randomized controlled trial comparing MoM versus MoP 28-mm articulations, focused on metal ions and implant survival. Patients and methods - 85 patients with a mean age of 65 years at surgery were randomized to a MoM (Metasul) or a MoP (Protasul) bearing. After 16 years, 38 patients had died and 4 had undergone revision surgery. 13 patients were unavailable for clinical follow-up, leaving 30 patients (n = 14 MoM and n = 16 MoP) for analysis of metal ion concentrations and clinical outcome. Results - 15-year implant survival was similar in both groups (MoM 96% [95% CI 88-100] versus MoP 97% [95% CI 91-100]). The mean serum cobalt concentration was 4-fold higher in the MoM (1.5 mu g/L) compared with the MoP cohort (0.4 mu g/L, p < 0.001) and the mean chromium concentration was double in the MoM (2.2 mu g/L) compared with the MoP cohort (1.0 mu g/L, p = 0.05). Mean creatinine levels were similar in both groups (MoM 93 mu mol/L versus MoP 92 mu mol/L). Harris hip scores differed only marginally between the MoM and MoP cohorts. Interpretation - This is the longest follow-up of a randomized trial on 28-mm MoM articulations, and although implant survival in the 2 groups was similar, metal ion concentrations remained elevated in the MoM cohort even in the long term.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Ortopedi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Orthopaedics (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy