SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Mauricio D)
 

Sökning: WFRF:(Mauricio D) > (2015-2019) > Microwave Sensors f...

Microwave Sensors for New Approach in Monitoring Hip Fracture Healing

Perez, Mauricio D. (författare)
Natl Technol Univ, Mendoza Reg Fac, Dept Elect, Electrostat & Dielect Mat Lab, Buenos Aires, DF, Argentina.
Redzwan, Syaiful Mohd Shah (författare)
Uppsala universitet,Fasta tillståndets elektronik,Microwave Group
Velander, Jacob (författare)
Uppsala universitet,Fasta tillståndets elektronik,Microwave Group
visa fler...
Raaben, Marco (författare)
UMC Utrecht, Surg, Traumatol, Heidelberglaan 100, NL-3584 CX Utrecht, Netherlands.
Asan, Noor Badariah (författare)
Uppsala universitet,Fasta tillståndets elektronik,Microwave Group
Blokhuis, Taco (författare)
Maastricht Univ, Med Ctr, Traumatol Dept, Maastricht, Netherlands.
Augustine, Robin, 1982- (författare)
Uppsala universitet,Fasta tillståndets elektronik,Microwave Group
visa färre...
Natl Technol Univ, Mendoza Reg Fac, Dept Elect, Electrostat & Dielect Mat Lab, Buenos Aires, DF, Argentina Fasta tillståndets elektronik (creator_code:org_t)
IEEE, 2017
2017
Engelska.
Ingår i: 2017 11th European Conference On Antennas And Propagation (EUCAP). - : IEEE. - 9788890701870 ; , s. 1838-1842
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • Cyber-Physical System (CPS) applications in lower-extremity bony-fracture rehabilitation systems require real-time biophysical data. Emerging and interesting solutions are microwave approaches that provide good contrast between hard and soft tissues and between local anomalies inside tissues. Preliminarily some contacting non-invasive planar methods have been investigated in their feasibility of detecting human tissues variations with promising results. In this work we introduce two new microwave planar sensors for a new approach of hip fracture healing follow-up tool. They are designed for improved resolution and penetration at frequencies between 1 to 3 GHz in detecting variations in bone, muscle or fat tissues that are expected during a rehabilitation process. The resonant devices are optimized using Frequency Domain Reflectometry and CST (R) environment and validated using clinical trials with volunteers. The new approach is validated using clinical trials with volunteers and patients. These outcomes further emphasize the feasibility of devising systems for fracture rehabilitation.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering (hsv//eng)

Nyckelord

microwave
biosensor
measurement
fracture rehabilitation

Publikations- och innehållstyp

ref (ämneskategori)
kon (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy