SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:uu-342858"
 

Sökning: id:"swepub:oai:DiVA.org:uu-342858" > Real-life clinical ...

  • Sarno, GiovannaUppsala universitet,Uppsala kliniska forskningscentrum (UCR),Kardiologi,kardiologi (författare)

Real-life clinical outcomes with everolimus eluting platinum chromium stent with an abluminal biodegradable polymer in patients from the Swedish Coronary Angiography and Angioplasty Registry (SCAAR)

  • Artikel/kapitelEngelska2017

Förlag, utgivningsår, omfång ...

  • 2017-05-22
  • Wiley,2017
  • printrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:uu-342858
  • https://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-342858URI
  • https://doi.org/10.1002/ccd.27030DOI
  • http://kipublications.ki.se/Default.aspx?queryparsed=id:137101155URI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • BACKGROUND: No previous studies have evaluated the performance of the Synergy stent in a large real-life population.OBJECTIVES: To describe the initial real-life experience with a novel everolimus eluting platinum chromium stent with abluminal biodegradable polymer (SYNERGY) in unselected patients from a nationwide registry.METHODS: All implanted Synergy stents were compared with other new generation drug eluting stents (n-DES) with >1,000 implantations in Sweden between March 2013 and October 2015. Restenosis, definite stent thrombosis (ST), myocardial infarction (MI) and death rates were assessed using propensity score and Cox regression analyses.RESULTS: A total of 7,886 of Synergy stents and 64,429 other n-DES (BioMatrix, N = 1,953; Orsiro, N = 4,946; Promus Element Plus, N= 2,543; Promus Premier, N= 20,414; Xience Xpedition, N= 7,971, Resolute/Resolute Integrity, N = 19,021; Ultimaster, N = 1,156; Resolute Onyx, N = 6,425) were implanted in 42,357 procedures. Restenosis and stent thrombosis occurred in 642 and 314 cases, respectively, in the overall population at 1 year. The cumulative rate of restenosis (1.1% vs. 1.0%, adjusted HR: 1.24 95% CI: 0.88-1.75; P = 0.21) and ST (0.4% vs. 0.5%, adjusted HR: 0.97; 95% CI: 0.63-1.50; P = 0.17) up to 1 year was low in both the Synergy group and the other n-DES group. Death occurred in 5.2% versus 4.5% (adjusted HR: 1.14; 95% CI: 0.96-1.36; P = 0.11) and MI in 3.2% versus 3.5%, (adjusted HR: 1.11; 95% CI: 0.93-1.33; P = 0.24) up to 1 year.CONCLUSIONS: In a large real-life population the Synergy stent appears to be safe and effective with a low rate of restenosis and ST comparable with other n-DES.

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Lagerqvist, Bo,1952-Uppsala universitet,Uppsala kliniska forskningscentrum (UCR),Kardiologi(Swepub:uu)bolager (författare)
  • Olivecrona, Göran (författare)
  • Varenhorst, Christoph,1977-Uppsala universitet,Kardiologi,Uppsala kliniska forskningscentrum (UCR)(Swepub:uu)chrva923 (författare)
  • Danielewicz, Mikael (författare)
  • Hambraeus, Kristina (författare)
  • Lindholm, Daniel,1982-Uppsala universitet,Uppsala kliniska forskningscentrum (UCR),Kardiologi(Swepub:uu)danli945 (författare)
  • Råmunddal, Truls (författare)
  • Witt, NilsKarolinska Institutet (författare)
  • James, Stefan,1964-Uppsala universitet,Uppsala kliniska forskningscentrum (UCR),Kardiologi(Swepub:uu)stjam367 (författare)
  • Uppsala universitetUppsala kliniska forskningscentrum (UCR) (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Catheterization and cardiovascular interventions: Wiley90:6, s. 881-8871522-19461522-726X

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy