SwePub
Sök i LIBRIS databas

  Extended search

WFRF:(Johansson Edvin)
 

Search: WFRF:(Johansson Edvin) > Evaluation of quant...

Evaluation of quantitative CMR perfusion imaging by comparison with simultaneous 15O-water-PET

Kero, Tanja (author)
Uppsala universitet,Radiologi,Medical Imaging Centre, Uppsala University Hospital
Johansson, Edvin (author)
Antaros Medical
Engström, Mathias (author)
GE Healthcare
show more...
Eggers, Kai M., 1962- (author)
Uppsala universitet,Kardiologi
Johansson, Lars (author)
Antaros Medical
Ahlström, Håkan, 1953- (author)
Uppsala universitet,Radiologi,Antaros Medical
Lubberink, Mark (author)
Uppsala universitet,Radiologi,Medical Physics, Uppsala University Hospital
show less...
 (creator_code:org_t)
2019-07-16
2021
English.
In: Journal of Nuclear Cardiology. - : Springer Science and Business Media LLC. - 1071-3581 .- 1532-6551. ; 28, s. 1252-1266
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • BackgroundWe assessed the quantitative accuracy of cardiac perfusion measurements using dynamic contrast-enhanced MRI with simultaneous 15O-water PET as reference with a fully integrated PET-MR scanner.Methods15 patients underwent simultaneous DCE MRI and 15O-water PET scans at rest and adenosine-stress on an integrated PET-MR scanner. Correlation and agreement between MRI- and PET-based global and regional MBF values were assessed using correlation and Bland–Altman analysis.ResultsThree subjects were excluded due to technical problems. Global mean (± SD) MBF values at rest and stress were 0.97 ± 0.27 and 3.19 ± 0.70 mL/g/min for MRI and 1.02 ± 0.28 and 3.13 ± 1.16 mL/g/min for PET (P = 0.66 and P = 0.81). The correlations between global and regional MRI- and PET-based MBF values were strong (r = 0.86 and r = 0.75). The biases were negligible for both global and regional MBF comparisons (0.01 and 0.00 mL/min/g for both), but the limits of agreement were wide for both global and regional MBF, with larger variability for high MBF-values.ConclusionThe correlation between simultaneous MBF measurements with DCE MRI and 15O-water PET measured in an integrated PET-MRI was strong but the agreement was only moderate indicating that MRI-based quantitative MBF measurements is not ready for clinical introduction.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kardiologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Cardiac and Cardiovascular Systems (hsv//eng)

Keyword

myocardial perfusion
myocardial blood flow
cardiac magnetic resonance imaging
positron emission tomography
quantitative modeling

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view