SwePub
Sök i LIBRIS databas

  Extended search

WFRF:(Fountain D)
 

Search: WFRF:(Fountain D) > (2018) > The performance of ...

The performance of anti-cyclic citrullinated peptide assays in diagnosing rheumatoid arthritis : a systematic review and meta-analysis

Mathsson Alm, Linda (author)
Uppsala universitet,Klinisk immunologi,Thermo Fisher Sci, Immuno Diagnost, Uppsala, Sweden.
Fountain, D. L. (author)
PHMR Ltd, London, England.
Cadwell, K. K. (author)
PHMR Ltd, London, England.
show more...
Madrigal, A. M. (author)
PHMR Ltd, London, England.
Gallo, G. (author)
Thermo Fisher Sci, Immuno Diagnost, Uppsala, Sweden.
Poorafshar, M. (author)
Thermo Fisher Sci, Immuno Diagnost, Uppsala, Sweden.
show less...
 (creator_code:org_t)
2018
2018
English.
In: Clinical and Experimental Rheumatology. - 0392-856X .- 1593-098X. ; 36:1, s. 144-152
  • Research review (peer-reviewed)
Abstract Subject headings
Close  
  • Objective. We assessed the ability of anti-cyclic citrullinated peptide (CCP) tests to diagnose rheumatoid arthritis (RA), comparing the effect of manufacturer assay type, study design (single-and two-gated) and duration of disease (early vs. established). Methods. We searched seven data-bases for relevant diagnostic studies containing data on CCP tests in known or suspected RA patients. We used a bi-variate model to produce summary estimates for test sensitivity, specificity, and positive and negative likelihood ratios. Summary Receiver Operating Characteristic (sROC) curves were derived to compare early versus established RA. Results. 83 studies were identified and included. For individual manufacturer tests there was considerable variation in both pooled sensitivity (range 67-83%) and specificity (range 90-96%) estimates. This heterogeneity was also observed when grouping studies into two-gated and single-gated designs. Study design and disease duration impacted on sensitivity, with single-gated study designs and early RA patients resulting in lower estimates than two-gated and established disease, respectively. Conclusion. This review highlights the large number of CCP tests that are now commercially available and the considerable variation in their diagnostic performance. This variation, although partly influenced in this analysis by the study design (single-gated vs. two-gated), seems to have different levels of impact depending on the manufacturers. The Thermo Fisher Scientific EliA and Inova Diagnostics Quanta Lite (CCP2) tests showed the least between-study variation in sensitivity and specificity suggesting they have the most consistent diagnostic performance overall.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Reumatologi och inflammation (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Rheumatology and Autoimmunity (hsv//eng)

Keyword

rheumatoid arthritis
systematic review
biomarkers
autoantigens and autoantibodies
laboratory diagnosis

Publication and Content Type

ref (subject category)
for (subject category)

Find in a library

To the university's database

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view