SwePub
Tyck till om SwePub Sök här!
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Auricchio Angelo)
 

Sökning: WFRF:(Auricchio Angelo) > (2015-2019) > Comparison of outco...

Comparison of outcomes in infected cardiovascular implantable electronic devices between complete, partial, and failed lead removal : an ESC-EHRA-EORP ELECTRa (European Lead Extraction ConTrolled) registry

Nof, Eyal (författare)
Bongiorni, Maria Grazia (författare)
Auricchio, Angelo (författare)
visa fler...
Butter, Christian (författare)
Dagres, Nikolaos (författare)
Deharo, Jean-Claude (författare)
Rinaldi, Christopher A (författare)
Maggioni, Aldo P (författare)
Kutarski, Andrzej (författare)
Kennergren, Charles (författare)
Laroche, Cécile (författare)
Milman, Anat (författare)
Beinart, Roy (författare)
Bogdan, Stefan (författare)
Mörtsell, David (författare)
Uppsala universitet,Kardiologi-arrytmi
Calvi, Valeria (författare)
Desiron, Quentin (författare)
Mansourati, Jacques (författare)
Blomström-Lundqvist, Carina (författare)
Uppsala universitet,Kardiologi-arrytmi,Kardiologi
Glikson, Michael (författare)
visa färre...
 (creator_code:org_t)
2019-10-18
2019
Engelska.
Ingår i: Europace. - : Oxford University Press. - 1099-5129 .- 1532-2092. ; 21:12, s. 1876-1889
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • AIMS: The present study sought to determine predictors for success and outcomes of patients who underwent cardiac implantable electronic devices (CIED) extraction indicated for systemic or local CIED related infection in particular where complete lead removal could not be achieved.METHODS AND RESULTS: ESC-EORP ELECTRa (European Lead Extraction ConTRolled Registry) is a European prospective lead extraction registry. Out of the total cohort, 1865/3510 (52.5%) patients underwent removal due to CIED related infection. Predictors and outcomes of failure were analysed. Complete removal was achieved in 1743 (93.5%) patients, partial (<4 cm of lead left) in 88 (4.7%), and failed (>4 cm of lead left) in 32 (1.8%) patients. Removal success was unrelated to type of CIED infection (pocket or systemic). Predictors for failure were older leads and older patients [odds ratio (OR) 1.14 (1.08-1.19), P < 0.0001 and OR 2.68 (1.22-5.91), P = 0.0146, respectively]. In analysis by lead, predictors for failure were: pacemaker vs. defibrillator removal and failure to engage the locking stylet all the way to the tip [OR 0.20 (0.04-0.95), P = 0.03 and OR 0.32 (0.13-0.74), P = 0.008, respectively]. Significantly higher complication rates were noted in the failure group (40.6% vs. 15.9 for partial and 8.7% for success groups, P < 0.0001). Failure to remove a lead was a strong predictor for in hospital mortality [hazard ratio of 2.05 (1.01-4.16), P = 0.046].CONCLUSION: A total of 6.5% of infected CIED patients failed attempted extraction. Only were >4 cm of lead remained resulted in higher procedural complications and mortality rates.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kardiologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Cardiac and Cardiovascular Systems (hsv//eng)

Nyckelord

Cardiac implantable electronic devices
Infection
Lead extraction
Registry

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

  • Europace (Sök värdpublikationen i LIBRIS)

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy