Sökning: WFRF:(Seemann Ulf) >
Very accurate cryog...
Very accurate cryogenic mechanisms for CRIRES+
-
- Lizon, Jean Louis (författare)
- European Org Astron Res Southern Hemisphere, Karl Schwarzschild Str 2, D-85748 Garching, Germany
-
- Klein, Barbara (författare)
- European Org Astron Res Southern Hemisphere, Karl Schwarzschild Str 2, D-85748 Garching, Germany
-
- Molina-Conde, Ignacio (författare)
- European Org Astron Res Southern Hemisphere, Karl Schwarzschild Str 2, D-85748 Garching, Germany
-
visa fler...
-
- Oliva, Ernesto (författare)
- Osservatorio Arcetri, INAF, Largo E Fermi 5, I-50125 Florence, Italy
-
- Escude, Guillem Anglada (författare)
- Univ Gottingen, Inst Astron, Friedrich Hund Pl 1, D-37077 Gottingen, Germany
-
- Bristow, Paul (författare)
- European Org Astron Res Southern Hemisphere, Karl Schwarzschild Str 2, D-85748 Garching, Germany
-
- Dorn, Reinhold J. (författare)
- European Org Astron Res Southern Hemisphere, Karl Schwarzschild Str 2, D-85748 Garching, Germany
-
- Follert, Roman (författare)
- Thuringer Landessternwarte Tautenburg, Sternwarte 5, D-07778 Tautenburg, Germany
-
- Hatzes, Artie (författare)
- Thuringer Landessternwarte Tautenburg, Sternwarte 5, D-07778 Tautenburg, Germany
-
- Heiter, Ulrike (författare)
- Uppsala universitet,Observationell astrofysik
-
- Ives, Derek (författare)
- European Org Astron Res Southern Hemisphere, Karl Schwarzschild Str 2, D-85748 Garching, Germany
-
- Jung, Yves (författare)
- European Org Astron Res Southern Hemisphere, Karl Schwarzschild Str 2, D-85748 Garching, Germany
-
- Lockhart, Matt (författare)
- European Org Astron Res Southern Hemisphere, Karl Schwarzschild Str 2, D-85748 Garching, Germany
-
- Marquart, Thomas, 1978- (författare)
- Uppsala universitet,Observationell astrofysik
-
- Origlia, Livia (författare)
- Osservatorio Bologna, INAF, Via Ranzani 1, I-40127 Bologna, Italy
-
- Pasquini, Luca (författare)
- European Org Astron Res Southern Hemisphere, Karl Schwarzschild Str 2, D-85748 Garching, Germany
-
- Paufique, Jerome (författare)
- European Org Astron Res Southern Hemisphere, Karl Schwarzschild Str 2, D-85748 Garching, Germany
-
- Pistunov, Nikolai (författare)
- Osservatorio Arcetri, INAF, Largo E Fermi 5, I-50125 Florence, Italy
-
- Reiners, Ansgar (författare)
- Univ Gottingen, Inst Astron, Friedrich Hund Pl 1, D-37077 Gottingen, Germany
-
- Smette, Alain (författare)
- European Org Astron Res Southern Hemisphere, Karl Schwarzschild Str 2, D-85748 Garching, Germany
-
- Smoker, Jonathan (författare)
- European Org Astron Res Southern Hemisphere, Karl Schwarzschild Str 2, D-85748 Garching, Germany
-
- Seemann, Ulf (författare)
- Univ Gottingen, Inst Astron, Friedrich Hund Pl 1, D-37077 Gottingen, Germany
-
- Stempels, Eric (författare)
- Osservatorio Arcetri, INAF, Largo E Fermi 5, I-50125 Florence, Italy
-
- Valenti, Elena (författare)
- European Org Astron Res Southern Hemisphere, Karl Schwarzschild Str 2, D-85748 Garching, Germany
-
visa färre...
-
(creator_code:org_t)
- SPIE-INT SOC OPTICAL ENGINEERING, 2018
- 2018
- Engelska.
-
Ingår i: OPTICAL AND INFRARED INTERFEROMETRY AND IMAGING VI. - : SPIE-INT SOC OPTICAL ENGINEERING. - 9781510619562
- Relaterad länk:
-
https://urn.kb.se/re...
-
visa fler...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- After 5 years of operation on the VLT, a large upgrade of CRIRES (the ESO Cryogenic InfraRed Echelle Spectrograph) was decided mainly in order to increase the efficiency. Using a cross dispersion design allows better wavelength coverage per exposure. This means a complete re-design of the cryogenic pre-optic which were including a pre-dispersion stage with a large prism as dispersive element. The new design requires a move of the entrance slit and associated decker toward the first intermediate focal plane right behind the window. Implement 2 functions with high positioning accuracy in a pre-defined and limited space was a real challenge. The design and the test results recorded in the ESO Cryogenic Test Facility are reported in this paper. The second critical function is the grating wheel which positions the 6 cross disperser gratings into the beam. The paper describes the design of the mechanism which includes a detente system in order to guaranty the 5 arc sec positioning reproducibility requested. The design includes also feedback system, based on switches, in order to ensure that the right grating is in position before starting a long exposure. The paper reports on the tests carried out at cryogenic temperature at the sub-system level. It also includes early performances recorded in the instrument along the first phases of the system test.
Ämnesord
- NATURVETENSKAP -- Fysik -- Astronomi, astrofysik och kosmologi (hsv//swe)
- NATURAL SCIENCES -- Physical Sciences -- Astronomy, Astrophysics and Cosmology (hsv//eng)
Nyckelord
- Cryogenic mechanism
- Spectrograph
- InfraRed instrument
Publikations- och innehållstyp
- ref (ämneskategori)
- kon (ämneskategori)
Hitta via bibliotek
Till lärosätets databas
- Av författaren/redakt...
-
Lizon, Jean Loui ...
-
Klein, Barbara
-
Molina-Conde, Ig ...
-
Oliva, Ernesto
-
Escude, Guillem ...
-
Bristow, Paul
-
visa fler...
-
Dorn, Reinhold J ...
-
Follert, Roman
-
Hatzes, Artie
-
Heiter, Ulrike
-
Ives, Derek
-
Jung, Yves
-
Lockhart, Matt
-
Marquart, Thomas ...
-
Origlia, Livia
-
Pasquini, Luca
-
Paufique, Jerome
-
Pistunov, Nikola ...
-
Reiners, Ansgar
-
Smette, Alain
-
Smoker, Jonathan
-
Seemann, Ulf
-
Stempels, Eric
-
Valenti, Elena
-
visa färre...
- Om ämnet
-
- NATURVETENSKAP
-
NATURVETENSKAP
-
och Fysik
-
och Astronomi astrof ...
- Artiklar i publikationen
-
OPTICAL AND INFR ...
- Av lärosätet
-
Uppsala universitet