Accuracy of determination of the glomerular filtration marker iohexol by European laboratories as monitored by external quality assessment

Nordin, Gunnar (författare)
Equalis, Uppsala, Sweden
Ekvall, Sara (författare)
Equalis, Uppsala, Sweden
Kristoffersson, Carolina (författare)
Equalis, Uppsala, Sweden
visa fler...
Jonsson, Ann-Sofie (författare)
Landstinget Varmland, Dept Clin Chem, Karlstad, Sweden
Bäck, Sten-Erik (författare)
Lund Univ Hosp, Dept Clin Chem, Lund, Sweden
Rollborn, Niclas (författare)
Uppsala universitet,Klinisk kemi
Larsson, Anders (författare)
Uppsala universitet,Klinisk kemi
visa färre...
 (creator_code:org_t)
2019-05-10
2019
Engelska.
Ingår i: Clinical Chemistry and Laboratory Medicine. - : Walter de Gruyter. - 1434-6621 .- 1437-4331. ; 57:7, s. 1006-1011
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background Glomerular filtration is the most important kidney function. The most accurate glomerular filtration rate (GFR) estimates are based on the clearance of exogenous filtration markers. Of these, iohexol is the only exogenous marker that is included in an external quality assessment (EQA) scheme. The aim of the present study was to evaluate the performance of the European laboratories participating in Equalis' EQA scheme for iohexol. Methods Weighed amounts of iohexol (Omnipaque) were added to plasma samples and distributed to laboratories participating in the EQA scheme for iohexol. All laboratories performed the assays in a blinded fashion. Results The number of participating laboratories varied between 27 and 34 during the study period. Iohexol was determined by HPLC in 77% of the laboratories and by UPLC/MS/MS methods in 15% of the laboratories. The mean interlaboratory coefficient of variation was 4.7% for the HPLC methods and 6.4% for the UPLC/MS/MS methods. The mean bias between calculated and measured iohexol values was -1.3 mg/L (95% confidence interval ±0.3) during the first part of the study period and 0.1 mg/L (±0.3) during the later part. Conclusions The low interlaboratory variation demonstrates that iohexol can be measured reliably by many laboratories and supports the use of iohexol as a GFR marker when there is a need for high quality GFR measurements.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Klinisk laboratoriemedicin (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Clinical Laboratory Medicine (hsv//eng)

Nyckelord

GFR
external quality assessment scheme
glomerular filtration rate
iohexol

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy