Pancreatic perfusion and its response to glucose as measured by simultaneous PET/MRI

Espes, Daniel, 1985- (författare)
Uppsala universitet,Institutionen för medicinsk cellbiologi,Transplantation och regenerativ medicin
Manell, Elin (författare)
Swedish University of Agricultural Sciences,Sveriges lantbruksuniversitet,Institutionen för kliniska vetenskaper (KV),Department of Clinical Sciences,Department of Clinical Sciences, Swedish University of Agricultural Sciences, Uppsala, Sweden
Rydén, Anneli (författare)
Swedish University of Agricultural Sciences,Sveriges lantbruksuniversitet,Institutionen för kliniska vetenskaper (KV),Department of Clinical Sciences,Department of Clinical Sciences, Swedish University of Agricultural Sciences, Uppsala, Sweden
visa fler...
Carlbom, Lina (författare)
Uppsala universitet,Radiologi
Weis, Jan, 1956- (författare)
Uppsala universitet,Radiologi
Jensen Waern, Marianne (författare)
Swedish University of Agricultural Sciences,Sveriges lantbruksuniversitet,Institutionen för kliniska vetenskaper (KV),Department of Clinical Sciences,Department of Clinical Sciences, Swedish University of Agricultural Sciences, Uppsala, Sweden
Jansson, Leif (författare)
Uppsala universitet,Institutionen för medicinsk cellbiologi
Eriksson, Olof (författare)
Uppsala universitet,Theranostics,Science for Life Laboratory, SciLifeLab
visa färre...
 (creator_code:org_t)
 
2019-04-26
2019
Engelska.
Ingår i: Acta Diabetologica. - : Springer. - 0940-5429 .- 1432-5233. ; 56:10, s. 1113-1120
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • AIMS: Perfusion of the pancreas and the islets of Langerhans is sensitive to physiological stimuli and is dysregulated in metabolic disease. Pancreatic perfusion can be assessed by both positron emission tomography (PET) and magnetic resonance imaging (MRI), but the methods have not been directly compared or benchmarked against the gold-standard microsphere technique.METHODS: Pigs (n = 4) were examined by [15O]H2O PET and intravoxel incoherent motion (IVIM) MRI technique simultaneously using a hybrid PET/MRI scanner. The pancreatic perfusion was measured both at basal conditions and after intravenous (IV) administration of up to 0.5 g/kg glucose.RESULTS: Pancreatic perfusion increased by 35%, 157%, and 29% after IV 0.5 g/kg glucose compared to during basal conditions, as assessed by [15O]H2O PET, IVIM MRI, and microspheres, respectively. There was a correlation between pancreatic perfusion as assessed by [15O]H2O PET and IVIM MRI (r = 0.81, R2 = 0.65, p < 0.01). The absolute quantification of pancreatic perfusion (ml/min/g) by [15O]H2O PET was within a 15% error of margin of the microsphere technique.CONCLUSION: Pancreatic perfusion by [15O]H2O PET was in agreement with the microsphere technique assessment. The IVIM MRI method has the potential to replace [15O]H2O PET if the pancreatic perfusion is sufficiently large, but not when absolute quantitation is required.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Endokrinologi och diabetes (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Endocrinology and Diabetes (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Medicinska och farmaceutiska grundvetenskaper -- Cell- och molekylärbiologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Basic Medicine -- Cell and Molecular Biology (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Medicinska och farmaceutiska grundvetenskaper -- Fysiologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Basic Medicine -- Physiology (hsv//eng)

Nyckelord

Diabetes
Hybrid scanner
PET/MRI scanner
Pancreas perfusion

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy