SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Westerberg Ulla)
 

Sökning: WFRF:(Westerberg Ulla) > (2000-2004) > [11C]Hyaluronan upt...

  • Lindqvist, UllaUppsala universitet,Reumatologi (författare)

[11C]Hyaluronan uptake with positron emission tomography in liver disease

  • Artikel/kapitelEngelska2000

Förlag, utgivningsår, omfång ...

  • 2001-12-24
  • Wiley,2000
  • printrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:uu-39281
  • https://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-39281URI
  • https://doi.org/10.1046/j.1365-2362.2000.00675.xDOI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:vet swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • Adress: Långström B, Univ Uppsala, Inst Chem, Box 531, S-75121 Uppsala, Sweden
  • BackgroundA hyaluronan-loading test has been developed for assessment of hyaluronan kinetics and applied in patients with liver and joint diseases. This test describes the metabolic process of hyaluronan but cannot define the specific contribution of different organs. A method for labelling of hyaluronan with the short-lived positron-emitting radionuclide 11C has been published and in this study applied in healthy subjects and liver diseases.Materials and methodsPositron emission tomography (PET) was used for the regional assessment and quantification of [11C]hyaluronan uptake in three healthy subjects, four patients with alcoholic liver cirrhosis, one with alcoholic hepatitis and one with liver steatosis. After intravenous administration of 60 MBq of 11C-labelled hyaluronan, a 55-min PET scan was performed over the liver and plasma radioactivity was analysed. Rate constants describing the transport of the [11C]hyaluronan tracer from plasma to the liver were calculated.ResultsHigh uptake was observed in the liver combined with a rapid elimination of tracer from plasma. The liver uptake rate (k1) was significantly lower in patients (0.018 min−1) than in healthy subjects (0.043 min−1, P = 0.002). The rate constants seem to be related to the severity of the disease as defined by the Child–Pugh score.ConclusionsThe study suggests that PET with [11C]hyaluronan could be an accurate method by which to assess liver dysfunction, in conditions where endothelial cell function is impaired. The possibility of quantification over extended portions of the body also opens up possibilities to explore regional differences in liver function and to assess other elimination routes of hyaluronan.

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Westerberg, GUppsala University PET Centre (författare)
  • Bergström, MUppsala University PET Centre (författare)
  • Torsteindottir, IUppsala universitet,Klinisk kemi (författare)
  • Gustafson, SUppsala universitet,Institutionen för medicinsk biokemi och mikrobiologi (författare)
  • Sundin, AndersUppsala universitet,Enheten för radiologi,Uppsala University PET Centre(Swepub:uu)anderssu (författare)
  • Lööf, LarsUppsala universitet,Centrum för klinisk forskning, Västerås,University Hospital, Uppsala, Sweden(Swepub:uu)larsloof (författare)
  • Långström, BengtUppsala University PET Centre(Swepub:uu)benglang (författare)
  • Uppsala universitetReumatologi (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:European Journal of Clinical Investigation: Wiley30:7, s. 600-6070014-29721365-2362

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy