SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Mauricio D)
 

Sökning: WFRF:(Mauricio D) > (2015-2019) > Analysis of Thickne...

Analysis of Thickness Variation in Biological Tissues using Microwave Sensors for Health Monitoring Applications

Redzwan, Syaiful (författare)
Uppsala universitet,Fasta tillståndets elektronik,Microwaves in Medical Engineering Group
Asan, Noor Badariah, 1984- (författare)
Uppsala universitet,Fasta tillståndets elektronik,Univ Teknikal Malaysia Melaka, Fac Elect & Comp Engn, Durian Tunggal 76100, Malaysia,Microwaves in Medical Engineering Group
Velander, Jacob (författare)
Uppsala universitet,Fasta tillståndets elektronik,Microwaves in Medical Engineering Group
visa fler...
Ebrahimizadeh, Javad (författare)
Uppsala universitet,Fasta tillståndets elektronik,Microwaves in Medical Engineering Group
Perez, Mauricio D. (författare)
Uppsala universitet,Fasta tillståndets elektronik,Microwaves in Medical Engineering Group
Mattsson, Viktor (författare)
Uppsala universitet,Fasta tillståndets elektronik,Microwaves in Medical Engineering Group
Blokhuis, Taco J. (författare)
Maastricht Univ, Traumatol Dept, Med Ctr, NL-6229 HX Maastricht, Netherlands
Augustine, Robin, 1982- (författare)
Uppsala universitet,Fasta tillståndets elektronik,Microwaves in Medical Engineering Group
visa färre...
 (creator_code:org_t)
2019
2019
Engelska.
Ingår i: IEEE Access. - 2169-3536. ; 7, s. 156033-156043
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Microwave sensing technique is a possible and attractive alternative modality to standard Xrays,magnetic resonance imaging, and computed tomography methods for medical diagnostic applications.This technique is beneficial since it uses non-ionizing radiation and that can be potentially used for themicrowave healthcare system. The main purpose of this paper is to present a microwave sensing techniqueto analyze the variations in biological tissue thickness, considering the effect of physiological and biologicalproperties on microwave signals. With this goal, we have developed a two-port non-invasive sensor systemcomposed of two split ring resonators (SRRs) operating at an Industrial, Scientific, and Medical frequencyband of 2.45 GHz. The system is verified using the amplitude and phase of the transmitted signal in ex-vivomodels, representing different tissue thicknesses. Clinical applications such as the diagnosis of muscularatrophy can be benefitted from this study.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Elektroteknik och elektronik -- Annan elektroteknik och elektronik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Electrical Engineering, Electronic Engineering, Information Engineering -- Other Electrical Engineering, Electronic Engineering, Information Engineering (hsv//eng)

Nyckelord

Engineering Science with specialization in Microwave Technology
Teknisk fysik med inriktning mot mikrovågsteknik

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy