SwePub
Sök i LIBRIS databas

  Utökad sökning

L773:1531 7129 OR L773:1537 4505
 

Sökning: L773:1531 7129 OR L773:1537 4505 > Incus Necrosis and ...

Incus Necrosis and Blood Supply : A Micro-CT and Synchrotron Imaging Study

Enghag, Sara (författare)
Uppsala universitet,Öron-, näs- och halssjukdomar
Strömbäck, Karin (författare)
Uppsala universitet,Öron-, näs- och halssjukdomar
Li, Hao, 1984- (författare)
Uppsala universitet,Institutionen för medicinska vetenskaper,Öron-, näs- och halssjukdomar
visa fler...
Rohani, Seyed Alireza (författare)
Western Univ, Dept Otolaryngol Head & Neck Surg, London, ON, Canada
Ladak, Hanif M. (författare)
Western Univ, Dept Otolaryngol Head & Neck Surg, London, ON, Canada;Western Univ, Dept Med Biophys, London, ON, Canada;Western Univ, Dept Elect & Comp Engn, London, ON, Canada
Rask-Andersen, Helge (författare)
Uppsala universitet,Öron-, näs- och halssjukdomar
Agrawal, Sumit (författare)
Western Univ, Dept Otolaryngol Head & Neck Surg, London, ON, Canada
visa färre...
 (creator_code:org_t)
LIPPINCOTT WILLIAMS & WILKINS, 2019
2019
Engelska.
Ingår i: Otology and Neurotology. - : LIPPINCOTT WILLIAMS & WILKINS. - 1531-7129 .- 1537-4505. ; 40:7, s. E713-E722
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background: Incus necrosis is a common complication following stapes surgery and is associated with impaired microcirculation. The objective of this study was to investigate the vascular anatomy of the human incus by using light microscopy, micro-computed tomography (micro-CT), and synchrotron phase-contrast imaging (SR-PCI) for a novel three-dimensional (3D) analysis of the middle ear, mucosal folds, major vascular pathways, and intraosseous vascular bone channels. Methods: One-hundred-and-fifty temporal bones from the Uppsala collection were analyzed under light microscopy. Twenty temporal bones underwent high-resolution micro-CT scanning, and an additional seven specimens underwent SR-PCI at the Canadian Lightsource in Saskatoon, Canada. One of these specimens was from an individual who had undergone stapes surgery. Data were processed with volume-rendering software to create 3D reconstructions using scalar opacity mapping for bone transparency, cropping, and soft tissue analyses. Results: Micro-CT and SR-PCI with 3D rendering revealed the extensive vascular plexus within the un-decalcified incus bone communicating with the exterior surface. The relationship between the vessels, lenticular process, and incudostape-dial joint were clearly observed. SR-PCI allowed for histologic-level detail while preserving the specimen and its 3D relationships. Conclusion: SR-PCI with 3D reconstructions confirmed the main vascular supply to the lenticular process along the intraosseous lenticular vessels. This is the first synchrotron analysis of a patient having undergone stapes surgery, and it suggests that incus necrosis associated with stapes surgery may be caused by a disruption of the lenticular blood flow induced by the prosthesis loop, and not by strangulation of mucosal vessels as has been previously described.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk bildbehandling (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Image Processing (hsv//eng)

Nyckelord

Incus necrosis
Micro-CT
Otosclerosis
Stapes surgery
Synchrotron imaging

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy