A Four-Layer Phantom for Testing In-Vitro Microwave-Based Sensing Approach in Intra-Cranial Pressure Monitoring

Velander, Jacob (författare)
Uppsala universitet,Fasta tillståndets elektronik
Redzwan, Syaiful (författare)
Uppsala universitet,Fasta tillståndets elektronik
Perez, Mauricio D. (författare)
Uppsala universitet,Fasta tillståndets elektronik
visa fler...
Asan, Noor Badariah, 1984- (författare)
Uppsala universitet,Fasta tillståndets elektronik
Nowinski, Daniel (författare)
Uppsala universitet,Plastikkirurgi
Lewén, Anders, 1965- (författare)
Uppsala universitet,Enblad: Neurokirurgi
Enblad, Per (författare)
Uppsala universitet,Enblad: Neurokirurgi
Augustine, Robin, 1982- (författare)
Uppsala universitet,Fasta tillståndets elektronik
visa färre...
 (creator_code:org_t)
IEEE, 2018
2018
Engelska.
Ingår i: Proceedings Of The 2018 IEEE/MTT-S International Microwave Biomedical Conference (IMBioC). - : IEEE. - 9781538659182 ; , s. 49-51
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • Multi-layer phantoms in proofs of concept, designs and validations of both microwave-based biomedical sensing and imaging system are becoming popular means to facilitate in-vitro experiments. In addition, they can contribute significantly to reduce animal use in scientific experimentation. In this paper, we design and fabricate a four-layer phantom composed of skin, skull, cerebrospinal fluid and brain mimic tissues to work between 2 and 3 GHz. In addition, the phantom incorporates a mechanism to produce pressure variation between the cerebrospinal fluid and the brain mimic tissues. This phantom is used in an in-vitro experiment to test and validate a new approach which could sense intra-cranial pressure variations through a microwave-based reflection method. The similarity of the phantom's tissues with human tissues from the viewpoint of the microwave response is analyzed in comparison with data from Italian Institute of Applied Physics in Florence. We found good agreement for the dielectric constant (Rel. Err. < 13 % for 68% of significance) in skin, cerebrospinal fluid and brain mimic tissues. For the skin, we got also good agreement for the loss tangent (Rel. Err. < 11 % for 68% of significance). The skull mimic phantom was stiff enough, but even presenting considerable errors, it was still good enough for the experiment. In addition, the capability of the phantom to operate at different pressures is discussed.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk bildbehandling (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Image Processing (hsv//eng)

Nyckelord

intra cranial pressure
split ring resonator (SRR) sensor
biocompatible
microwave technique

Publikations- och innehållstyp

ref (ämneskategori)
kon (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy