SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Rask M)
 

Sökning: WFRF:(Rask M) > Characterization of...

Characterization of the human helicotrema : implications for cochlear duct length and frequency mapping

Helpard, Luke (författare)
Western Univ, Sch Biomed Engn, London, ON, Canada
Li, Hao, 1984- (författare)
Uppsala universitet,Öron-, näs- och halssjukdomar
Rask-Andersen, Helge (författare)
Uppsala universitet,Öron-, näs- och halssjukdomar
visa fler...
Ladak, Hanif M. (författare)
Western Univ, Sch Biomed Engn, London, ON, Canada;Western Univ, Dept Otolaryngol Head & Neck Surg, London, ON, Canada;Western Univ, Dept Med Biophys, London, ON, Canada;Western Univ, Dept Elect & Comp Engn, London, ON, Canada
Agrawal, Sumit K. (författare)
Western Univ, Sch Biomed Engn, London, ON, Canada;Western Univ, Dept Otolaryngol Head & Neck Surg, London, ON, Canada;Western Univ, Dept Med Biophys, London, ON, Canada;Western Univ, Dept Elect & Comp Engn, London, ON, Canada
visa färre...
 (creator_code:org_t)
2020-01-06
2020
Engelska.
Ingår i: Journal of Otolaryngology - Head & Neck Surgery. - : BMC. - 1916-0216. ; 49
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background: Despite significant anatomical variation amongst patients, cochlear implant frequency-mapping has traditionally followed a patient-independent approach. Basilar membrane (BM) length is required for patient-specific frequency-mapping, however cochlear duct length (CDL) measurements generally extend to the apical tip of the entire cochlea or have no clearly defined end-point. By characterizing the length between the end of the BM and the apical tip of the entire cochlea (helicotrema length), current CDL models can be corrected to obtain the appropriate BM length. Synchrotron radiation phase-contrast imaging has made this analysis possible due to the soft-tissue contrast through the entire cochlear apex.Methods: Helicotrema linear length and helicotrema angular length measurements were performed on synchrotron radiation phase-contrast imaging data of 14 cadaveric human cochleae. On a sub-set of six samples, the CDL to the apical tip of the entire cochlea (CDLTIP) and the BM length (CDLBM) were determined. Regression analysis was performed to assess the relationship between CDLTIP and CDLBM.Results: The mean helicotrema linear length and helicotrema angular length values were 1.6 +/- 0.9 mm and 67.8 +/- 37.9 degrees, respectively. Regression analysis revealed the following relationship between CDLTIP and CDLBM: CDLBM = 0.88(CDLTIP) + 3.71 (R-2 = 0.995).Conclusion: This is the first known study to characterize the length of the helicotrema in the context of CDL measurements. It was determined that the distance between the end of the BM and the tip of the entire cochlea is clinically consequential. A relationship was determined that can predict the BM length of an individual patient based on their respective CDL measured to the apical tip of the cochlea.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Oto-rhino-laryngologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Otorhinolaryngology (hsv//eng)

Nyckelord

Helicotrema
Helicotrema size
Cochlear duct length
Basilar membrane
Cochlear apex
Cochlear implant
Frequency mapping
Synchrotron radiation

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy