Optimizing image quality, radiation dosage to the patient and to the detector in pediatric chest radiography : a phantom study of a portable digital radiography system

Shahgeldi, Kaveh (författare)
Uppsala universitet,Centrum för klinisk forskning, Gävleborg
Sjöberg, Tommy (författare)
Uppsala universitet,Institutionen för kirurgiska vetenskaper
Nordström, Jonny (författare)
Uppsala universitet,Centrum för klinisk forskning, Gävleborg
visa fler...
Lesanu, Radu (författare)
Gavle Cent Hosp, Dept Imaging & Funct Med, Div Diagnost, S-80188 Gavle, Region Gavlebor, Sweden
Svahn, Tony Martin (författare)
Uppsala universitet,Centrum för klinisk forskning, Gävleborg
visa färre...
 (creator_code:org_t)
2019-03-27
2019
Engelska.
Ingår i: Radiation Protection Dosimetry. - : OXFORD UNIV PRESS. - 0144-8420 .- 1742-3406. ; 185:4, s. 414-420
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The present work aimed to optimize exposure settings in pediatric digital chest radiography (DR) with regard to image quality and radiation dosage. A pediatric phantom was imaged with a portable DR unit to examine different exposure settings (range: 75-109 kVp; 0.3-1.28 mAs) for patients of 10-20 kg. Fourteen experienced radiologists compared the structural image quality of the images with a reference image (85 kVp/1.28 mAs). A multiple-reader multiple-case analysis of the radiologists' interpretations was performed. Effective dose was computed and standardized exposure indices (EIs) were extracted for the different exposure settings. For the lowest tube voltage setting (75 kVp/1.28 mAs), radiation dosage could be reduced with 35% relative the reference settings without compromising image quality (p > 0.05). EI was within recommendations (250 +/- 100). Lower tube voltage in pediatric DR permitted a dose reduction at maintained quality for the physical aspects and diagnostic performance. Other weight-classes should be examined and adjusted accordingly.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy