SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:uu-437381"
 

Sökning: id:"swepub:oai:DiVA.org:uu-437381" > Influence of patien...

  • Nordström, JonnyUppsala universitet,Radiologi,Centrum för klinisk forskning, Gävleborg (författare)

Influence of patient motion on quantitative accuracy in cardiac 15O-water positron emission tomography.

  • Artikel/kapitelEngelska2022

Förlag, utgivningsår, omfång ...

  • 2021-03-02
  • Springer Nature,2022
  • electronicrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:uu-437381
  • https://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-437381URI
  • https://doi.org/10.1007/s12350-021-02550-9DOI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • BACKGROUND: Patient motion is a common problem during cardiac PET. The purpose of the present study was to investigate to what extent motions influence the quantitative accuracy of cardiac 15O-water PET/CT and to develop a method for automated motion detection.METHOD: Frequency and magnitude of motion was assessed visually using data from 50 clinical 15O-water PET/CT scans. Simulations of 4 types of motions with amplitude of 5 to 20 mm were performed based on data from 10 scans. An automated motion detection algorithm was evaluated on clinical and simulated motion data. MBF and PTF of all simulated scans were compared to the original scan used as reference.RESULTS: Patient motion was detected in 68% of clinical cases by visual inspection. All observed motions were small with amplitudes less than half the LV wall thickness. A clear pattern of motion influence was seen in the simulations with a decrease of myocardial blood flow (MBF) in the region of myocardium to where the motion was directed. The perfusable tissue fraction (PTF) trended in the opposite direction. Global absolute average deviation of MBF was 3.1% ± 1.8% and 7.3% ± 6.3% for motions with maximum amplitudes of 5 and 20 mm, respectively. Automated motion detection showed a sensitivity of 90% for simulated motions ≥ 10 mm but struggled with the smaller (≤ 5 mm) simulated (sensitivity 45%) and clinical motions (accuracy 48%).CONCLUSION: Patient motion can impair the quantitative accuracy of MBF. However, at typically occurring levels of patient motion, effects are similar to or only slightly larger than inter-observer variability, and downstream clinical effects are likely negligible.

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Harms, Hendrik J (författare)
  • Kero, TanjaUppsala universitet,Radiologi(Swepub:uu)tanke311 (författare)
  • Sörensen, JensUppsala universitet,Radiologi,Klinisk fysiologi(Swepub:uu)jenssore (författare)
  • Lubberink, MarkUppsala universitet,Radiologi,Institutionen för immunologi, genetik och patologi(Swepub:uu)marklubb (författare)
  • Uppsala universitetRadiologi (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Journal of Nuclear Cardiology: Springer Nature29:4, s. 1742-17521071-35811532-6551

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Nordström, Jonny
Harms, Hendrik J
Kero, Tanja
Sörensen, Jens
Lubberink, Mark
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Kardiologi
Artiklar i publikationen
Journal of Nucle ...
Av lärosätet
Uppsala universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy