SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:uu-437401"
 

Sökning: onr:"swepub:oai:DiVA.org:uu-437401" > End-to-end validati...

  • Bernchou, UffeOdense Univ Hosp, Dept Oncol, Lab Radiat Phys, Odense, Denmark.;Univ Southern Denmark, Dept Clin Res, Odense, Denmark. (författare)

End-to-end validation of the geometric dose delivery performance of MR linac adaptive radiotherapy

  • Artikel/kapitelEngelska2021

Förlag, utgivningsår, omfång ...

  • 2021-02-11
  • Institute of Physics Publishing (IOPP),2021
  • printrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:uu-437401
  • https://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-437401URI
  • https://doi.org/10.1088/1361-6560/abd3edDOI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • The clinical introduction of hybrid magnetic resonance (MR) guided radiotherapy (RT) delivery systems has led to the need to validate the end-to-end dose delivery performance on such machines. In the current study, an MR visible phantom was developed and used to test the spatial deviation between planned and delivered dose at two 1.5 T MR linear accelerator (MR linac) systems, including pre-treatment imaging, dose planning, online imaging, image registration, plan adaptation, and dose delivery. The phantom consisted of 3D printed plastic and MR visible silicone rubber. It was designed to minimise air gaps close to the radiochromic film used as a dosimeter. Furthermore, the phantom was designed to allow submillimetre, reproducible positioning of the film in the phantom. At both MR linac systems, 54 complete adaptive, MR guided RT workflow sessions were performed. To test the dose delivery performance of the MR linac systems in various adaptive RT (ART) scenarios, the sessions comprised a range of systematic positional shifts of the phantom and imaging or plan adaptation conditions. In each workflow session, the positional translation between the film and the adaptive planned dose was determined. The results showed that the accuracy of the MR linac systems was between 0.1 and 0.9 mm depending on direction. The highest mean deviance observed was in the posterior-anterior direction, and the direction of the error was consistent between centres. The precision of the systems was related to whether the workflow utilized the internal image registration algorithm of the MR linac. Workflows using the internal registration algorithm led to a worse precision (0.2-0.7 mm) compared to workflows where the algorithm was decoupled (0.2 mm). In summary, the spatial deviation between planned and delivered dose of MR-guided ART at the two MR linac systems was well below 1 mm and thus acceptable for clinical use.

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Christiansen, Rasmus L.Odense Univ Hosp, Dept Oncol, Lab Radiat Phys, Odense, Denmark.;Univ Southern Denmark, Dept Clin Res, Odense, Denmark. (författare)
  • Bertelsen, AndersOdense Univ Hosp, Dept Oncol, Lab Radiat Phys, Odense, Denmark. (författare)
  • Tilly, David,1974-Uppsala universitet,Medicinsk strålningsvetenskap,Akad Hosp, Med Phys, Uppsala, Sweden.;Elekta Instruments AB, Stockholm, Sweden.(Swepub:uu)daver488 (författare)
  • Riis, Hans L.Odense Univ Hosp, Dept Oncol, Lab Radiat Phys, Odense, Denmark.;Univ Southern Denmark, Dept Clin Res, Odense, Denmark. (författare)
  • Jensen, Henrik R.Odense Univ Hosp, Dept Oncol, Lab Radiat Phys, Odense, Denmark. (författare)
  • Mahmood, FaisalOdense Univ Hosp, Dept Oncol, Lab Radiat Phys, Odense, Denmark.;Univ Southern Denmark, Dept Clin Res, Odense, Denmark. (författare)
  • Hansen, Christian R.Odense Univ Hosp, Dept Oncol, Lab Radiat Phys, Odense, Denmark.;Univ Southern Denmark, Dept Clin Res, Odense, Denmark. (författare)
  • Hansen, Vibeke N.Odense Univ Hosp, Dept Oncol, Lab Radiat Phys, Odense, Denmark. (författare)
  • Schytte, TineOdense Univ Hosp, Dept Oncol, Odense, Denmark. (författare)
  • Brink, CarstenOdense Univ Hosp, Dept Oncol, Lab Radiat Phys, Odense, Denmark.;Univ Southern Denmark, Dept Clin Res, Odense, Denmark. (författare)
  • Odense Univ Hosp, Dept Oncol, Lab Radiat Phys, Odense, Denmark.;Univ Southern Denmark, Dept Clin Res, Odense, Denmark.Odense Univ Hosp, Dept Oncol, Lab Radiat Phys, Odense, Denmark. (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Physics in Medicine and Biology: Institute of Physics Publishing (IOPP)66:40031-91551361-6560

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy