SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:uu-442277"
 

Sökning: id:"swepub:oai:DiVA.org:uu-442277" > Minimum Distance-Ba...

  • Samanta, Anik KumarIIT Kharagpur, Adv Technol Dev Ctr, Kharagpur 721302, W Bengal, India. (författare)

Minimum Distance-Based Detection of Incipient Induction Motor Faults Using Rayleigh Quotient Spectrum of Conditioned Vibration Signal

  • Artikel/kapitelEngelska2021

Förlag, utgivningsår, omfång ...

  • Institute of Electrical and Electronics Engineers (IEEE),2021
  • printrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:uu-442277
  • https://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-442277URI
  • https://doi.org/10.1109/TIM.2020.3047433DOI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • In this article, we propose a single-vibration sensor-based method for detecting incipient faults in squirrel cage induction motors (SCIMs). We consider defects in different parts of the bearing (inner raceway, outer raceway, cage train, and rolling element) and in a single bar of the rotor. The vibration signal is dominated by the fundamental rotational frequency and its harmonics. The dominant components result in numerical errors while estimating the relatively indistinct fault-specific spectral components. In this article, we precondition the vibration signal by suppressing multiple dominant components using an extended Kalman filter-based method. The suppression of the dominant components reduces the spectral leakage, exposes minute fault components, and improves the overall amplitude estimation. Subsequently, we estimate the fault frequency and amplitude using an accurate and low-complexity Rayleigh-quotient-based spectral estimator. The thresholds for fault detection are determined from a small number of healthy data, and an adaptive minimum distance-based detector is used for hypothesis testing. The proposed test improves detection and reduces false alarms under noisy conditions. We test the complete algorithm using data from a 22-kW SCIM laboratory setup. The proposed method has achieved 100% accuracy with the publicly available 12-kHz drive-end bearing data from Case Western Reserve University, Cleveland, OH, USA.

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Routray, AurobindaIIT Kharagpur, Dept Elect Engn, Kharagpur 721302, W Bengal, India. (författare)
  • Khare, Swanand R.IIT Kharagpur, Dept Math, Kharagpur 721302, W Bengal, India. (författare)
  • Naha, ArunavaUppsala universitet,Signaler och system(Swepub:uu)aruna171 (författare)
  • IIT Kharagpur, Adv Technol Dev Ctr, Kharagpur 721302, W Bengal, India.IIT Kharagpur, Dept Elect Engn, Kharagpur 721302, W Bengal, India. (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:IEEE Transactions on Instrumentation and Measurement: Institute of Electrical and Electronics Engineers (IEEE)700018-94561557-9662

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy