SwePub
Tyck till om SwePub Sök här!
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Svensson Lennart 1954 )
 

Sökning: WFRF:(Svensson Lennart 1954 ) > Dual energy CT find...

Dual energy CT findings in gout with rapid kilovoltage-switching source with gemstone scintillator detector

Svensson, Elin (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiologi,Institute of Clinical Sciences, Department of Radiology
Aurell, Ylva (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiologi,Institute of Clinical Sciences, Department of Radiology
Jacobsson, Lennart T. H., 1954 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för medicin, avdelningen för reumatologi och inflammationsforskning,Institute of Medicine, Department of Rheumatology and Inflammation Research
visa fler...
Landgren, Anton J., 1989 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för medicin, avdelningen för reumatologi och inflammationsforskning,Institute of Medicine, Department of Rheumatology and Inflammation Research
Sigurdardottir, Valgerdur (författare)
Gothenburg University,Göteborgs universitet,Uppsala universitet,Centrum för klinisk forskning Dalarna,Sahlgrens Acad, Dept Rheumatol & Inflammat Res, Gothenburg, Sweden.,Institutionen för medicin, avdelningen för reumatologi och inflammationsforskning,Institute of Medicine, Department of Rheumatology and Inflammation Research
Dehlin, Mats, 1968 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för medicin, avdelningen för reumatologi och inflammationsforskning,Institute of Medicine, Department of Rheumatology and Inflammation Research
visa färre...
 (creator_code:org_t)
2020-01-17
2020
Engelska.
Ingår i: BMC Rheumatology. - : SPRINGERNATURE. - 2520-1026. ; 4:1
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • BackgroundA definite diagnosis of gout requires demonstration of monosodium urate crystals in synovial fluid or in tophi, which in clinical practice today seldom is done. Dual energy CT (DECT) has repeatedly been shown to be able to detect monosodium urate crystals in tissues, hence being an alternative method to synovial fluid microscopy. The vast majority of these studies were performed with CT scanners with two X-ray tubes. In the present study we aim to investigate if and at what locations DECT with rapid kilovoltage-switching source with gemstone scintillator detector (GSI) can identify MSU crystals in patients with clinically diagnosed gout. We also performed a reliability study between two independent readings.MethodsPatients with new or established gout who had been examined with DECT GSI scanning of the feet at Sahlgrenska University Hospital, Molndal between 2015 and 2018 were identified. Their medical records were sought for gout disease characteristics using a structured protocol. Urate deposits in MTP1, MTP 2-5, ankle/midfoot joints and tendons were scored semiquantatively in both feet and presence of artifacts in nail and skin as well as beam hardening and noise were recorded. Two radiologists performed two combined readings and scoring of the images, thus consensus was reached over the scoring at each occasion (Espeland et al., BMC Med Imaging. 2013;13:4). The two readings were compared with kappa statistics.ResultsDECT GSI could identify urate deposits in the feet of all 55 participants with gout. Deposits were identified in the MTP-joints of all subjects but were also present in ankle/midfoot joints and tendons in 96 and 75% respectively. Deposition of urate was predicted by longer disease duration (Spearman's Rho 0.64, p <.0001) and presence of tophi (p =0.0005). Artifacts were common and mostly found in the nails (73%), a minority displayed skin artifacts (31%) while beam hardening and noise was rare. The agreement between the two readings was good (=0.66, 95% CI=0.61-0.71).ConclusionThe validity of DECT GSI in gout is supported by the identification of urate in all patients with clinical gout and the good correlations with clinical characteristics. The occurrence of artifacts was relatively low with expected locations.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Reumatologi och inflammation (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Rheumatology and Autoimmunity (hsv//eng)

Nyckelord

Gout
Dual energy CT
Monosodium urate crystals
Foot
Diagnostic imaging

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy