SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Maud L.)
 

Sökning: WFRF:(Maud L.) > MAS :

MAS : Standalone Microwave Resonator to Assess Muscle Quality

Mattsson, Viktor (författare)
Uppsala universitet,Fasta tillståndets elektronik
Ackermans, Leanne L. G. C. (författare)
Maastricht Univ, Dept Traumatol, Med Ctr, NL-6229 HX Maastricht, Netherlands.
Mandal, Bappaditya (författare)
Uppsala universitet,Fasta tillståndets elektronik
visa fler...
Perez, Mauricio D. (författare)
Uppsala universitet,Fasta tillståndets elektronik
Vesseur, Maud A. M. (författare)
Maastricht Univ, Dept Traumatol, Med Ctr, NL-6229 HX Maastricht, Netherlands.
Meaney, Paul (författare)
Dartmouth Coll, Thayer Sch Engn, Hanover, NH 03755 USA.
Ten Bosch, Jan A. (författare)
Maastricht Univ, Dept Traumatol, Med Ctr, NL-6229 HX Maastricht, Netherlands.
Blokhuis, Taco J. (författare)
Maastricht Univ, Dept Traumatol, Med Ctr, NL-6229 HX Maastricht, Netherlands.
Augustine, Robin, 1982- (författare)
Uppsala universitet,Fasta tillståndets elektronik
visa färre...
 (creator_code:org_t)
2021-08-14
2021
Engelska.
Ingår i: Sensors. - : MDPI. - 1424-8220. ; 21:16
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Microwave-based sensing for tissue analysis is recently gaining interest due to advantages such as non-ionizing radiation and non-invasiveness. We have developed a set of transmission sensors for microwave-based real-time sensing to quantify muscle mass and quality. In connection, we verified the sensors by 3D simulations, tested them in a laboratory on a homogeneous three-layer tissue model, and collected pilot clinical data in 20 patients and 25 healthy volunteers. This report focuses on initial sensor designs for the Muscle Analyzer System (MAS), their simulation, laboratory trials and clinical trials followed by developing three new sensors and their performance comparison. In the clinical studies, correlation studies were done to compare MAS performance with other clinical standards, specifically the skeletal muscle index, for muscle mass quantification. The results showed limited signal penetration depth for the Split Ring Resonator (SRR) sensor. New sensors were designed incorporating Substrate Integrated Waveguides (SIW) and a bandstop filter to overcome this problem. The sensors were validated through 3D simulations in which they showed increased penetration depth through tissue when compared to the SRR. The second-generation sensors offer higher penetration depth which will improve clinical data collection and validation. The bandstop filter is fabricated and studied in a group of volunteers, showing more reliable data that warrants further continuation of this development.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk laboratorie- och mätteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Laboratory and Measurements Technologies (hsv//eng)

Nyckelord

muscle quality
sarcopenia
microwave sensing
bandstop filter
substrate integrated waveguides

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

  • Sensors (Sök värdpublikationen i LIBRIS)

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy