SwePub
Sök i LIBRIS databas

  Utökad sökning

L773:1522 2594 OR L773:0740 3194
 

Sökning: L773:1522 2594 OR L773:0740 3194 > (2020-2024) > Motion-insensitive ...

Motion-insensitive susceptibility weighted imaging.

Berglund, Johan (författare)
Karolinska Institutet
Sprenger, Tim (författare)
van Niekerk, Adam (författare)
Karolinska Institutet
visa fler...
Rydén, Henric (författare)
Karolinska Institutet
Avventi, Enrico (författare)
Norbeck, Ola (författare)
Karolinska Institutet
Skare, Stefan (författare)
Karolinska Institutet
visa färre...
 (creator_code:org_t)
2021-06-02
2021
Engelska.
Ingår i: Magnetic Resonance in Medicine. - : Wiley. - 0740-3194 .- 1522-2594. ; 86:4, s. 1970-1982
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • PURPOSE: To enable SWI that is robust to severe head movement.METHODS: Prospective motion correction using a markerless optical tracker was applied to all pulse sequences. Three-dimensional gradient-echo and 3D EPI were used as reference sequences, but were expected to be sensitive to motion-induced B0 changes, as the long TE required for SWI allows phase discrepancies to accumulate between shots. Therefore, 2D interleaved snapshot EPI was investigated for motion-robust SWI and compared with conventional 2D EPI. Repeated signal averages were retrospectively corrected for motion. The sequences were evaluated at 3 T through controlled motion experiments involving two cooperative volunteers and SWI of a tumor patient.RESULTS: The performed continuous head motion was in the range of 5-8° rotations. The image quality of the 3D sequences and conventional 2D EPI was poor unless the rotational motion axis was parallel to B0 . Interleaved snapshot EPI had minimal intraslice phase discrepancies due to its small temporal footprint. Phase inconsistency between signal averages was well tolerated due to the high-pass filter effect of the SWI processing. Interleaved snapshot EPI with prospective and retrospective motion correction demonstrated similar image quality, regardless of whether motion was present. Lesion depiction was equal to 3D EPI with matching resolution.CONCLUSION: Susceptibility-based imaging can be severely corrupted by head movement despite accurate prospective motion correction. Interleaved snapshot EPI is a superior alternative for patients who are prone to move and offers SWI which is insensitive to motion when combined with prospective and retrospective motion correction.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

echo planar imaging
interleaved snapshot EPI
movement correction
prospective motion correction
susceptibility weighted imaging

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy