SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Ojwang Dickson O.)
 

Sökning: WFRF:(Ojwang Dickson O.) > Investigation of Va...

Investigation of Valence Mixing in Sodium-Ion Battery Cathode Material Prussian White by Mossbauer Spectroscopy

Ericsson, Tore (författare)
Uppsala universitet,Institutionen för geovetenskaper,Materialfysik,Institutionen för kemi - Ångström
Häggström, Lennart (författare)
Uppsala universitet,Materialfysik,Institutionen för kemi - Ångström
Ojwang, Dickson O. (författare)
Uppsala universitet,Institutionen för kemi - Ångström
visa fler...
Brant, William (författare)
Uppsala universitet,Strukturkemi
visa färre...
 (creator_code:org_t)
2022-07-04
2022
Engelska.
Ingår i: Frontiers in Energy Research. - : Frontiers Media S.A.. - 2296-598X. ; 10
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Prussian white (PW), Na2Fe [Fe(CN)(6)], is a highly attractive cathode material for sustainable sodium-ion batteries due to its high theoretical capacity of similar to 170 mAhg(-1) and low-cost synthesis. However, there exists significant variability in the reported electrochemical performance. This variability originates from compositional flexibility possible for all Prussian blue analogs (PBAs) and is exasperated by the difficulty of accurately quantifying the specific composition of PW. This work presents a means of accurately quantifying the vacancy content, valence distribution, and, consequently, the overall composition of PW via Mossbauer spectroscopy. PW cathode material with three different sodium contents was investigated at 295 and 90 K. The observation of only two iron environments for the fully sodiated compound indicated the absence of [Fe(CN)(6)](4-) vacancies. Due to intervalence charge transfer between iron centers at 295 K, accurate determination of valences was not possible. However, by observing the trend of spectral intensities and center shift for the nitrogen-bound and carbon-bound iron, respectively, at 90 K, valence mixing between the iron sites could be quantified. By accounting for valence mixing, the sum of iron valences agreed with the sodium content determined from elemental analysis. Without an agreement between the total valence sum and the determined composition, there exists uncertainty around the accuracy of the elemental analysis and vacancy content determination. Thus, this study offers one more stepping stone toward a more rigorous characterization of composition in PW, which will enable further optimization of properties for battery applications. More broadly, the approach is valuable for characterizing iron-based PBAs in applications where precise composition, valence determination, and control are desired.

Ämnesord

NATURVETENSKAP  -- Kemi -- Materialkemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences -- Materials Chemistry (hsv//eng)

Nyckelord

Prussian white
Mossbauer spectroscopy
sodium-ion battery
intervalence charge transfer
low-defect
cathode

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Ericsson, Tore
Häggström, Lenna ...
Ojwang, Dickson ...
Brant, William
Om ämnet
NATURVETENSKAP
NATURVETENSKAP
och Kemi
och Materialkemi
Artiklar i publikationen
Frontiers in Ene ...
Av lärosätet
Uppsala universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy