SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Sundin Anders 1966)
 

Sökning: WFRF:(Sundin Anders 1966) > Comparison of 68Ga-...

Comparison of 68Ga-DOTATATE and 177Lu-DOTATATE kinetics in neuroendocrine tumors

Ilan, Ezgi (författare)
Uppsala universitet,Radiologi
Velikyan, Irina, 1966- (författare)
Uppsala universitet,Radiologi
Sandström, Mattias (författare)
Uppsala universitet,Radiologi
visa fler...
Andersson, Camilla (författare)
Uppsala universitet,Radiologi
Jahn, Ulrika (författare)
Uppsala universitet,Radiologi
Sundin, Anders, 1954- (författare)
Uppsala universitet,Radiologi,Institutionen för medicinska vetenskaper
Lubberink, Mark (författare)
Uppsala universitet,Institutionen för medicinska vetenskaper,Radiologi
visa färre...
 (creator_code:org_t)
Engelska.
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Absorbed dose planning prior peptide receptor radionuclide therapy (PRRT) with 177Lu-DOTATATE would allow maximization of the absorbed dose to tumor tissue whilst minimizing the risk for side-effects in healthy organs. Unfortunately, dosimetry during 177Lu-DOTATATE is only possible post therapy and using 68Ga-DOTATATE to act as surrogate for 177Lu-DOTATATE could potentially enable prediction of absorbed doses prior PRRT with 177Lu-DOTATATE. The aim of this study was to compare uptake and kinetics of 68Ga-DOTATATE and 177Lu-DOTATATE in tumors by performing dynamic or serial scans with both radiopharmaceuticals in the same patients.  Methods Six NET patients underwent a 45-min dynamic PET scan after injection of 124 ±38 MBq 68Ga-DOTATATE and serial SPECT scans after a bolus injection of 500 ± 0 MBq 177Lu-DOTATATE assuring similar peptide content in the radiopharmaceuticals. Tumor and whole-blood SUV, tumor-to-blood-ratio (TBR), and net influx rate (Ki) were determined for 68Ga-DOTATATE and 177Lu-DOTATATE. Ki was determined by non-linear regression of an irreversible two-tissue compartment model with a loss parameter and by the Patlak method. Results In majority of tumors, tumor SUV was higher in 68Ga-DOTATATE than in 177Lu-DOTATATE and whole-blood SUV was lower in 68Ga-DOTATATE than in 177Lu-DOTATATE, resulting in a lower TBR for 68Ga-DOTATATE than for 177Lu-DOTATATE. For Ki, Spearman correlation was 0.55 between 68Ga- DOTATATE and 177Lu-DOTATATE with a Demining regression slope of 0.93. For Patlak based Ki (with correction for partial volume effect based on data <100 min p.i. for 177Lu-DOTATATE), the Spearman correlation was 0.90 and with a Deming regression slope close to 1 (0.83). Using a later time interval (with correction for partial volume effect based on data >100 min p.i) for the Patlak analysis also resulted in high correlation (0.87) but the Deming regression slope was 0.18. Conclusion Linear relation with good agreement was found between the SUVs of 68Ga-DOTATATE and 177Lu-DOTATATE. Similar Ki was observed for 68Ga-DOTATATE and 177Lu-DOTATATE during early time interval (<100 min p.i of 177Lu-DOTATATE) however not during late time interval (>100 min p.i.). Hence, late kinetics of 177Lu-DOTATATE cannot be predicted using 68Ga-DOTATATE PET.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

68Ga-DOTATATE
177Lu-DOTATATE
PRRT
PET/CT
SPECT/CT
NET
somatostatin receptors
theranostics
Medicinsk radiofysik
Medical Radiophysics

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy