SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:uu-504226"
 

Sökning: onr:"swepub:oai:DiVA.org:uu-504226" > In an endotoxaemic ...

In an endotoxaemic model, antibiotic clearance can be affected by different central venous catheter positions, during renal replacement therapy

Bandert, Anna (författare)
Uppsala universitet,Anestesiologi och intensivvård,Centrum för klinisk forskning, Gävleborg,Department of Anaesthesiology and Intensive Care, Gävle Hospital, Lasarettvägen 1, 80324, Gävle, Sweden
Lipcsey, Miklós (författare)
Uppsala universitet,Hedenstiernalaboratoriet
Frithiof, Robert (författare)
Uppsala universitet,Anestesiologi och intensivvård
visa fler...
Larsson, Anders (författare)
Uppsala universitet,Klinisk kemi
Smekal, David, 1971- (författare)
Uppsala universitet,Anestesiologi och intensivvård
visa färre...
 (creator_code:org_t)
Springer Nature, 2023
2023
Engelska.
Ingår i: Intensive Care Medicine Experimental. - : Springer Nature. - 2197-425X. ; 11:1
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • BACKGROUND: In intensive care, different central venous catheters (CVC) are often used for infusion of drugs. If a patient is treated with continuous renal replacement therapy (CRRT) a second catheter, a central venous dialysis catheter (CVDC), is needed. Placing the catheters close together might pose a risk that a drug infused in a CVC could be directly aspirated into a CRRT machine and cleared from the blood without giving the effect intended. The purpose of this study was to elucidate if drug clearance is affected by different catheter placement, during CRRT. In this endotoxaemic animal model, an infusion of antibiotics was administered in a CVC placed in the external jugular vein (EJV). Antibiotic clearance was compared, whether CRRT was through a CVDC placed in the same EJV, or in a femoral vein (FV). To reach a target mean arterial pressure (MAP), noradrenaline was infused through the CVC and the dose was compared between the CDVDs.RESULTS: The main finding in this study was that clearance of antibiotics was higher when both catheter tips were in the EJV, close together, compared to in different vessels, during CRRT. The clearance of gentamicin was 21.0 ± 7.3 vs 15.5 ± 4.2 mL/min (p 0.006) and vancomycin 19.3 ± 4.9 vs 15.8 ± 7.1 mL/min (p 0.021). The noradrenaline dose to maintain a target MAP also showed greater variance with both catheters in the EJV, compared to when catheters were placed in different vessels.CONCLUSION: The results in this study indicate that close placement of central venous catheter tips could lead to unreliable drug concentration, due to direct aspiration, during CRRT.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Anestesi och intensivvård (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Anesthesiology and Intensive Care (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Urologi och njurmedicin (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Urology and Nephrology (hsv//eng)

Nyckelord

Acute kidney injury
Central venous catheter
Continuous renal replacement therapy antibiotic concentration
Dialysis
Intensive care
Sepsis

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy