SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Nguyen Van Thanh)
 

Sökning: WFRF:(Nguyen Van Thanh) > Enhancement of NH3 ...

Enhancement of NH3 gas sensing with Ag-Pt co-catalyst on SnO2 nanofilm towards medical diagnosis

Duy, Nguyen Van (författare)
Hanoi Univ Sci & Technol HUST, ITIMS, Hanoi, Vietnam
Trang, Duong Thi Thuy (författare)
Hanoi Univ Sci & Technol HUST, ITIMS, Hanoi, Vietnam
Le, Dang Thi Thanh (författare)
Hanoi Univ Sci & Technol HUST, ITIMS, Hanoi, Vietnam
visa fler...
Hung, Chu Manh (författare)
Hanoi Univ Sci & Technol HUST, ITIMS, Hanoi, Vietnam
Tonezzer, Matteo (författare)
Univ Trento, Fdn Edmund Mach, Ctr Agr Food Environm, Via E Mach 1, I-38010 San Michele All Adige, Italy.;IMEM CNR, Via Cascata 56 C, I-38123 Trento, Italy
Nguyen, Hugo, 1955- (författare)
Uppsala universitet,Mikrosystemteknik
Hoa, Nguyen Duc (författare)
Hanoi Univ Sci & Technol HUST, ITIMS, Hanoi, Vietnam
visa färre...
Hanoi Univ Sci & Technol HUST, ITIMS, Hanoi, Vietnam Univ Trento, Fdn Edmund Mach, Ctr Agr Food Environm, Via E Mach 1, I-38010 San Michele All Adige, Italy;IMEM CNR, Via Cascata 56 C, I-38123 Trento, Italy (creator_code:org_t)
Elsevier, 2023
2023
Engelska.
Ingår i: Thin Solid Films. - : Elsevier. - 0040-6090 .- 1879-2731. ; 767
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Exhaled breath analysis is a noninvasive diagnostic method for fatal disease monitoring and screening, which is recently gained extensive interest of researchers worldwide emphasizing on the development of effective chemiresistive gas sensor for practical application. Here, the Ag-Pt bimetallic nanoparticles were used to deco-rate nanofilms of SnO2 making different gas sensors with high performance. We found that the bimetal alloy improved the sensor performance significantly with super sensitivity as compared with the separate Ag and Pt catalyst. The right ratio of the bimetal made the sensor very sensitive to NH3, so that it was able to quickly (12 s) detect 1 parts-per-million of NH3 with a response of 4.31 at a temperature of 250 degrees C. The sensor limit of detection for NH3 was less than 10 parts-per-billion. The response of the sensor was negligibly affected by humidity and interfering gases. The results showed that the tiny, robust, and inexpensive sensor developed in this work can be used in breath analysis for early diagnosis via NH3 monitoring.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Annan teknik -- Övrig annan teknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Other Engineering and Technologies -- Other Engineering and Technologies not elsewhere specified (hsv//eng)

Nyckelord

Ammonia
Gas sensor
Tin dioxide
Nanofilm
Silver-platinum alloy
Breath diagnosis

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy