SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Andrén Per E. Professor 1957 )
 

Sökning: WFRF:(Andrén Per E. Professor 1957 ) > Zero-Degree Celsius...

Zero-Degree Celsius Capillary Electrophoresis Electrospray Ionization for Hydrogen Exchange Mass Spectrometry

Aerts, Jordan (författare)
Uppsala universitet,Institutionen för farmaceutisk biovetenskap,Department of Pharmaceutical Biosciences, Uppsala University, Uppsala751 24, Sweden
Andrén, Per E., Professor, 1957- (författare)
Uppsala universitet,MMS, medicinsk masspektrometri,Science for Life Laboratory, SciLifeLab,Department of Pharmaceutical Biosciences, Uppsala University, Uppsala751 24, Sweden;Science for Life Laboratory, Spatial Mass Spectrometry, Uppsala University, Uppsala751 24, Sweden
Jansson, Erik T., Docent, tekn. dr. 1984- (författare)
Uppsala universitet,Institutionen för farmaceutisk biovetenskap,Department of Pharmaceutical Biosciences, Uppsala University, Uppsala751 24, Sweden
 (creator_code:org_t)
2022-12-22
2023
Engelska.
Ingår i: Analytical Chemistry. - : Springer Nature. - 0003-2700 .- 1520-6882. ; 95:2, s. 1149-1158
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Currently, fast liquid chromatographic separations at low temperatures are exclusively used for the separation of peptides generated in hydrogen deuterium exchange (HDX) workflows. However, it has been suggested that capillary electrophoresis may be a better option for use with HDX. We performed in solution HDX on peptides and bovine hemoglobin (Hb) followed by quenching, pepsin digestion, and cold capillary electrophoretic separation coupled with mass spectrometry (MS) detection for benchmarking a laboratory-built HDX–MS platform. We found that capillaries with a neutral coating to eliminate electroosmotic flow and adsorptive processes provided fast separations with upper limit peak capacities surpassing 170. In contrast, uncoated capillaries achieved 30% higher deuterium retention for an angiotensin II peptide standard owing to faster separations but with only half the peak capacity of coated capillaries. Data obtained using two different separation conditions on peptic digests of Hb showed strong agreement of the relative deuterium uptake between methods. Processed data for denatured versus native Hb after deuterium labeling for the longest timepoint in this study (50,000 s) also showed agreement with subunit interaction sites determined by crystallographic methods. All proteomic data are available under DOI: 10.6019/PXD034245.

Ämnesord

NATURVETENSKAP  -- Kemi -- Analytisk kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences -- Analytical Chemistry (hsv//eng)

Nyckelord

Kemi med inriktning mot analytisk kemi
Chemistry with specialization in Analytical Chemistry

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Aerts, Jordan
Andrén, Per E., ...
Jansson, Erik T. ...
Om ämnet
NATURVETENSKAP
NATURVETENSKAP
och Kemi
och Analytisk kemi
Artiklar i publikationen
Analytical Chemi ...
Av lärosätet
Uppsala universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy