Determining primary stability for adhesively stabilized dental implants

Andersen, Ole Zoffmann (författare)
Univ Bern, Dept Periodontol, Frieburg str 7, CH-3010 Bern, Switzerland.;Inst Straumann AG, Basel, Switzerland.
Bellon, Benjamin (författare)
Inst Straumann AG, Basel, Switzerland.;Univ Tampere, Fac Med & Hlth Technol, Tampere, Finland.
Lamkaouchi, Maryam (författare)
Univ Bordeaux, INSERM BIOTIS, U1026, Bordeaux, France.
visa fler...
Brunelli, Marzia (författare)
Inst Straumann AG, Basel, Switzerland.
Wei, Qiuju (författare)
Univ Bern, Dept Periodontol, Frieburg str 7, CH-3010 Bern, Switzerland.
Procter, Philip (författare)
Uppsala universitet,Tillämpad materialvetenskap
Pippenger, Benjamin E. (författare)
Univ Bern, Dept Periodontol, Frieburg str 7, CH-3010 Bern, Switzerland.;Inst Straumann AG, Basel, Switzerland.
visa färre...
Univ Bern, Dept Periodontol, Frieburg str 7, CH-3010 Bern, Switzerland;Inst Straumann AG, Basel, Switzerland. Inst Straumann AG, Basel, Switzerland.;Univ Tampere, Fac Med & Hlth Technol, Tampere, Finland. (creator_code:org_t)
Springer, 2023
2023
Engelska.
Ingår i: Clinical Oral Investigations. - : Springer. - 1432-6981 .- 1436-3771. ; 27, s. 3741-3748
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Objectives: To examine factors influencing the primary stability of dental implants when stabilized in over-sized osteotomies using a calcium phosphate-based adhesive cement was the objective.Methods: Using implant removal torque measurements as a surrogate for primary stability, we examined the influence of implant design features (diameter, surface area, and thread design), along with cement gap size and curing time, on the resulting primary implant stability.Results: Removal torque values scaled with implant surface area and increasing implant diameters. Cement gap size did not alter the median removal torque values; however, larger gaps were associated with an increased spread of the measured values. Among the removal torque values measured, all were found to be above 32 Ncm which is an insertion torque threshold value commonly recommended for immediate loading protocols.Conclusion: The adhesive cement show potential for offering primary implant stability for different dental implant designs. In this study, the primary parameters influencing the measured removal torque values were the implant surface area and diameter. As the liquid cement prevents the use of insertion torque, considering the relationship between insertion and removal torque, removal torque can be considered a reliable surrogate for primary implant stability for bench and pre-clinical settings.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Odontologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Dentistry (hsv//eng)

Nyckelord

Bioadhesive
Dental implant
Primary stability
Removal torque
In vitro

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy