SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Sladoje Nataša)
 

Sökning: WFRF:(Sladoje Nataša) > Automated detection...

Automated detection, segmentation and measurement of major vessels and the trachea in CT pulmonary angiography

Kahraman, Ali T. (författare)
Uppsala universitet,Cancerprecisionsmedicin
Fröding, Tomas (författare)
Nyköping Hosp, Dept Radiol, S-61139 Nyköping, Sweden.
Toumpanakis, Dimitrios (författare)
Uppsala universitet,Radiologi,Uppsala Univ Hosp, Dept Radiol, S-75185 Uppsala, Sweden.
visa fler...
Sladoje, Nataša (författare)
Uppsala universitet,Avdelningen Vi3,Bildanalys och människa-datorinteraktion
Sjöblom, Tobias (författare)
Uppsala universitet,Cancerprecisionsmedicin
visa färre...
 (creator_code:org_t)
Springer Nature, 2023
2023
Engelska.
Ingår i: Scientific Reports. - : Springer Nature. - 2045-2322. ; 13
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Mediastinal structure measurements are important for the radiologist's review of computed tomography pulmonary angiography (CTPA) examinations. In the reporting process, radiologists make measurements of diameters, volumes, and organ densities for image quality assessment and risk stratification. However, manual measurement of these features is time consuming. Here, we sought to develop a time-saving automated algorithm that can accurately detect, segment and measure mediastinal structures in routine clinical CTPA examinations. In this study, 700 CTPA examinations collected and annotated. Of these, a training set of 180 examinations were used to develop a fully automated deterministic algorithm. On the test set of 520 examinations, two radiologists validated the detection and segmentation performance quantitatively, and ground truth was annotated to validate the measurement performance. External validation was performed in 47 CTPAs from two independent datasets. The system had 86-100% detection and segmentation accuracy in the different tasks. The automatic measurements correlated well to those of the radiologist (Pearson's r 0.68-0.99). Taken together, the fully automated algorithm accurately detected, segmented, and measured mediastinal structures in routine CTPA examinations having an adequate representation of common artifacts and medical conditions.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk bildbehandling (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Image Processing (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy