SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Karacagil Sadettin)
 

Sökning: WFRF:(Karacagil Sadettin) > (1995-1999) > A modified techniqu...

A modified technique of ultrasonic triplex scanning of the lower extremity arteries

Karacagil, Sadettin (författare)
Uppsala universitet,Institutionen för kirurgiska vetenskaper
Granbo, Agneta (författare)
Jonsson, Marie-Louise (författare)
visa fler...
Almgren, Bo (författare)
Uppsala universitet,Institutionen för kirurgiska vetenskaper
Bergqvist, David (författare)
Uppsala universitet,Institutionen för kirurgiska vetenskaper
visa färre...
 (creator_code:org_t)
1996
1996
Engelska.
Ingår i: Upsala Journal of Medical Sciences. - 0300-9734 .- 2000-1967. ; 101:1, s. 113-120
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • This study was undertaken to evaluate the utility of a modified technique of triplex scanning of the lower extremity arteries in 20 subjects without any clinical signs of arterial disease. The distal aorta and iliac arteries were examined with the subject in supine position and lying slightly on the opposite side. By moderate compression of the probe towards the psoas muscle and directing it over the iliac arteries with slight medial retraction of the abdomen, satisfactory visualization of the common and external arteries with 7.5 MHz high resolution imaging and a 5.6 MHz doppler probe were obtained in 56 of 80 segments (70%). In obese individuals it was necessary to use 5 MHz probe for satisfactory scanning of the aortic bifurcation and common iliac arteries. The distal superficial femoral, popliteal and tibioperoneal trunk segments were examined with the patient prone and the knee slightly flexed. Peak systolic, early diastolic reverse and late diastolic forward flow velocities were studied together with measurement of the arterial diemeters, which demonstrated wide variations. This study suggests that satisfactory scanning of the iliac and femoropopliteal arteries with the described technique can be achieved in the majority of subjects with a superficial high resolution probe. The combination of 7.5 MHz two-dimensional imaging with a 5.6 MHz pulsed wave Doppler probe offers optimal information of these arteries in nonobese individuals.

Nyckelord

MEDICINE
MEDICIN

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy