SwePub
Sök i LIBRIS databas

  Utökad sökning

L773:1532 2165 OR L773:1078 5884
 

Sökning: L773:1532 2165 OR L773:1078 5884 > (1995-1999) > Value of duplex sca...

Value of duplex scanning in evaluation of crural and foot arteries in limbs with severe lower limb ischaemia : a prospective comparison with angiography

Karacagil, Sadettin (författare)
Uppsala universitet,Institutionen för kirurgiska vetenskaper
Löfberg, Anne-Marie (författare)
Granbo, Agneta (författare)
visa fler...
Lörelius, Lar-Erik (författare)
Bergqvist, David (författare)
Uppsala universitet,Institutionen för kirurgiska vetenskaper
visa färre...
 (creator_code:org_t)
1996
1996
Engelska.
Ingår i: European Journal of Vascular and Endovascular Surgery. - 1078-5884 .- 1532-2165. ; 12:3, s. 300-303
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • OBJECTIVES: To compare Duplex scanning with angiography for evaluation of crural and pedal arteries in limbs with lower limb ischaemia. DESIGN: The findings obtained during Duplex scanning and angiography were prospectively compared in a blinded manner. SETTING: Departments of Surgery, Diagnostic Radiology and Clinical Physiology, University Hospital. MATERIALS: Duplex scanning and selective angiography of femoropopliteal, crural and foot arteries were performed in 40 limbs (38 patients, 480 segments) with intermittent claudication (n = 6), rest pain (n = 13) and ulcer/gangrene (n = 19). Each arterial segment were graded into four categories: normal, < or = 50% diameter reduction, > 50% diameter reduction and occlusion. Pedal arteries were evaluated as patency or occlusion of dorsal pedal artery and plantar arch. Chief outcome measures: Accuracy (AC), sensitivity (SE), specificity (SP), positive predictive (PPV), negative predictive (NPV) and kappa values. MAIN RESULTS: The Duplex scanning of the tibioperoneal trunk, crural and pedal arteries had an accuracy of 80% (kappa = 0.6). The SE, SP, PPV and NPV values were 83%, 77%, 79% and 81%, respectively. The SP was relatively low for the peroneal artery (58%) compared to the others. CONCLUSIONS: The results demonstrate the feasibility and reliability of Duplex scanning in detecting crural and pedal artery lesions in lower limbs with severe ischaemia.

Nyckelord

MEDICINE
MEDICIN

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy