SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Logason Karl)
 

Sökning: WFRF:(Logason Karl) > The importance of D...

The importance of Doppler angle of insonation on differentiation between 50-69% and 70-99% carotid artery stenosis

Logason, Karl (författare)
Uppsala universitet,Institutionen för kirurgiska vetenskaper,Vascular Surgery
Bärlin, T. (författare)
Jonsson, Marie-Louise (författare)
visa fler...
Boström, Annika (författare)
Uppsala universitet,Institutionen för kirurgiska vetenskaper,Vascular Surgery
Hårdemark, Hans-Göran (författare)
Uppsala universitet,Institutionen för neurovetenskap,Neurology
Karacagil, Sadettin (författare)
Uppsala universitet,Institutionen för kirurgiska vetenskaper,Vascular Surgery
visa färre...
 (creator_code:org_t)
Elsevier BV, 2001
2001
Engelska.
Ingår i: European Journal of Vascular and Endovascular Surgery. - : Elsevier BV. - 1078-5884 .- 1532-2165. ; 21:4, s. 311-313
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • AIM: to investigate the importance of Doppler angle differentiating between 50-69% and >/=70% internal carotid artery (ICA) stenosis. MATERIAL AND METHODS: fifty-one patients with a previous diagnosis of 50-69% ICA stenosis (n =53) were re-evaluated by duplex scanning. Spectral Doppler velocity waveforms were obtained from common carotid (CCA), ICA and external (ECA) carotid arteries with the same Doppler angle of insonation as used at the initial duplex scanning, followed by repeated measurements with a fixed 60 degrees angle of insonation. RESULTS: the peak systolic velocity (PSV) in the ICA was 181+/-55 cm/s (mean+/-SD) at the second duplex scanning when the same angle of insonation (mean 46 degrees +/-9) was used as during the initial investigation. When the examination was done with a 60 degrees angle of insonation, PSV ICA was 261+/-96 cm/s (mean+/-SD). In fifteen arteries the estimated degree of ICA stenosis changed from 50-69% to 70-99% due to the application of a fixed Doppler angle of insonation at 60 degrees. CONCLUSION: the Doppler angle of insonation has a significant effect on spectral Doppler velocity measurements. It is crucial that duplex criteria are standardised with a fixed angle of insonation and that this angle is consistently used during velocity estimations.

Nyckelord

Doppler
Angle of insonation
Carotid artery
MEDICINE
MEDICIN

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy