SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Logason Karl)
 

Sökning: WFRF:(Logason Karl) > Duplex scan finding...

Duplex scan findings in patients with spontaneous cervical artery dissections

Logason, Karl (författare)
Uppsala universitet,Institutionen för kirurgiska vetenskaper,Vascular Surgery
Hårdemark, Hans-Göran (författare)
Uppsala universitet,Institutionen för neurovetenskap,Neurology
Bärlin, T. (författare)
visa fler...
Bergqvist, David (författare)
Uppsala universitet,Institutionen för kirurgiska vetenskaper,Vascular Surgery
Ahlstöm, H. (författare)
Uppsala universitet,Institutionen för onkologi, radiologi och klinisk immunologi
Karacagil, Sadettin (författare)
Uppsala universitet,Institutionen för kirurgiska vetenskaper,Vascular Surgery
visa färre...
 (creator_code:org_t)
Elsevier BV, 2002
2002
Engelska.
Ingår i: European Journal of Vascular and Endovascular Surgery. - : Elsevier BV. - 1078-5884 .- 1532-2165. ; 23:4, s. 295-298
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • AIM: to report duplex scan findings in patients with spontaneous internal carotid artery (ICA) or vertebral artery (VA) dissection. MATERIAL AND METHODS: the records of 24 patients (13 males and 11 females, median age 48 years [range 25-68 years]) with spontaneous extracranial ICA dissection (n=20) or VA dissection (n=4), identified between January 1995 and December 1999, were retrospectively analysed. RESULTS: four different abnormal flow patterns were observed in patients with ICA dissection: (a) absence of flow (15%), (b) staccato flow (50%), (c) reduced flow velocity (25%) and, (d) stenotic flow (10%). B-mode ultrasound showed a homogenous echolucent lesion in eight patients and a double lumen in two. Staccato flow along the entire ICA was observed in only four patients without verified dissection during the study period. In the four patients with VA dissection, duplex scanning demonstrated staccato flow in three and reversed low-amplitude pulsatile flow in one. CONCLUSION: duplex scanning is an important noninvasive diagnostic modality in patients with cervical artery dissection. Staccato flow along the extracranial ICA strongly indicates the presence of spontaneous ICA dissection.

Nyckelord

MEDICINE
MEDICIN

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy