SwePub
Sök i LIBRIS databas

  Extended search

id:"swepub:oai:DiVA.org:uu-91654"
 

Search: id:"swepub:oai:DiVA.org:uu-91654" > Tomography for part...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist
  • Jacobsson Svärd, StaffanUppsala universitet,Institutionen för kärn- och partikelfysik,Tillämpad kärnfysik (author)

Tomography for partial-defect verification : experiences from measurements using different devices

  • Article/chapterEnglish2006

Publisher, publication year, extent ...

  • 2006
  • printrdacarrier

Numbers

  • LIBRIS-ID:oai:DiVA.org:uu-91654
  • https://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-91654URI

Supplementary language notes

  • Language:English
  • Summary in:English

Part of subdatabase

Classification

  • Subject category:ref swepub-contenttype
  • Subject category:art swepub-publicationtype

Notes

  • Three devices of different types have been used in tomographic measurements for the purpose of partial-defect verification on the single-rod level. The devices range from a laboratory device used in measurements on a fuel model to an in-pool device used in measurements on irradiated fuel in a fuel-handling pool.The tomographic technique accounted for in this paper involves measurements of the gamma-ray flux distribution around a fuel assembly followed by computer-aided reconstruction of the internal source distribution. The results are rod-by-rod values of the relative concentrations of selected gamma-emitting isotopes. Also cross-sectional images are obtained.The tomographic technique presented here has proven to be robust and reliable. In laboratory experiments on a fuel model, reconstructions of relative rod-by-rod activities have been obtained with 1.5 % accuracy (1 σ). Using an in-pool device in measurements on fuel with a cooling time of about 4 weeks, data on fuel rods have been obtained in agreement with production-code calculations. Furthermore, tomographic images of good quality have been acquired.The applicability of the tomographic technique for partial-defect verification on the single-rod level has been investigated and demonstrated. The gamma-ray source concentration reconstructed in a position corresponding to a removed or replaced rod has been significantly lower than that of normal rods.Finally, requirements and properties of a device for tomographic measurements on nuclear fuel are discussed. It is argued that the use of a detector system with high energy resolution and high peak efficiency in connection to spectroscopic peak analysis is beneficial.

Subject headings and genre

Added entries (persons, corporate bodies, meetings, titles ...)

  • Håkansson, AneUppsala universitet,Tillämpad kärnfysik (author)
  • Bäcklin, AndersUppsala universitet,Tillämpad kärnfysik (author)
  • Jansson, Peter,1971-Uppsala universitet,Institutionen för strålningsvetenskap(Swepub:uu)petejans (author)
  • Osifo, OtasowieUppsala universitet,Institutionen för strålningsvetenskap (author)
  • Willman, ChristoferUppsala universitet,Institutionen för strålningsvetenskap (author)
  • Uppsala universitetInstitutionen för kärn- och partikelfysik (creator_code:org_t)

Related titles

  • In:ESARDA Bulletin33, s. 15-250392-3029

Internet link

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view