SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Nyholm Leif)
 

Sökning: WFRF:(Nyholm Leif) > Interference of the...

Interference of the electrospray voltage on chromatographic separations using porous graphitic carbon columns

Törnkvist, Anna (författare)
Uppsala universitet,Avdelningen för analytisk kemi
Nilsson, Stefan (författare)
Uppsala universitet,Avdelningen för analytisk kemi
Amirkhani, Ardeshir (författare)
Uppsala universitet,Avdelningen för analytisk kemi
visa fler...
Nyholm, Lena (författare)
Nyholm, Leif (författare)
Uppsala universitet,Avdelningen för analytisk kemi
visa färre...
 (creator_code:org_t)
2004-02-24
2004
Engelska.
Ingår i: Journal of Mass Spectrometry. - : Wiley. - 1076-5174 .- 1096-9888. ; 39:2, s. 216-222
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The electrospray ionization (ESI) voltage is shown to interfere with liquid chromatographic separations performed with packed porous graphitic carbon (PGC) capillary columns. This interference is ascribed to the presence of an electric field over the conductive column in the absence of an earth point between the column and the ESI emitter. The current evolved alters the chromatographic behavior of the catecholamine metabolite 3-O-methyl-DOPA significantly, as both peak splitting and a dramatic decrease in the retention time were observed. Furthermore, the response from the mass spectrometer was decreased by 33% at the same time. A related compound, tyrosine, exhibited decreased retention times but no peak splitting, whereas no shifts in the retention times (or peak splitting) were seen for the less retained dopamine and noradrenaline. When the current through the PGC column was eliminated by the use of an earth point between the column and the ESI emitter, the chromatographic behavior of the column was found to return slowly to normal after hours of equilibration with 60 : 40 (v/v) methanol-ammonium formate buffer of pH 2.9. The behavior of the PGC column with and without the earth point was found to be highly reproducible during a period of 1 month. We propose that the effect of the ESI voltage on the chromatographic behavior of the PGC column is due to associated redox reactions affecting both the PGC particles and the analytes. It is concluded that (for analytical reasons), care should be taken to ensure that no current is flowing through the chromatographic system when interfacing PGC columns, and conducting parts in general, to ESI mass spectrometry.

Ämnesord

NATURVETENSKAP  -- Kemi -- Oorganisk kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences -- Inorganic Chemistry (hsv//eng)

Nyckelord

catecholamine
dopamine
electrochemistry
porous graphitic carbon
electrospray
mass spectrometry
liquid chromatography

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Törnkvist, Anna
Nilsson, Stefan
Amirkhani, Ardes ...
Nyholm, Lena
Nyholm, Leif
Om ämnet
NATURVETENSKAP
NATURVETENSKAP
och Kemi
och Oorganisk kemi
Artiklar i publikationen
Journal of Mass ...
Av lärosätet
Uppsala universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy