SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Ahnesjö Anders Professor)
 

Sökning: WFRF:(Ahnesjö Anders Professor) > Dosimetry Studies o...

Dosimetry Studies of Different Radiotherapy Applications using Monte Carlo Radiation Transport Calculations

Abbasinejad Enger, Shirin, 1975- (författare)
Uppsala universitet,Institutionen för onkologi, radiologi och klinisk immunologi
Lundqvist, Hans, Professor (preses)
Uppsala universitet,Institutionen för onkologi, radiologi och klinisk immunologi
Ahnesjö, Anders, Professor (preses)
Uppsala universitet,Institutionen för onkologi, radiologi och klinisk immunologi
visa fler...
Gudowska, Irena, Docent (opponent)
KI
visa färre...
 (creator_code:org_t)
ISBN 9789155472795
Uppsala : Universitetsbiblioteket, 2008
Engelska 49 s.
Serie: Digital Comprehensive Summaries of Uppsala Dissertations from the Faculty of Medicine, 1651-6206 ; 375
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)
Abstract Ämnesord
Stäng  
  • Developing radiation delivery systems for optimisation of absorbed dose to the target without normal tissue toxicity requires advanced calculations for transport of radiation. In this thesis absorbed dose and fluence in different radiotherapy applications were calculated by using Monte Carlo (MC) simulations.In paper I-III external neutron activation of gadolinium (Gd) for intravascular brachytherapy (GdNCB) and tumour therapy (GdNCT) was investigated. MC codes MCNP and GEANT4 were compared. MCNP was chosen for neutron capture reaction calculations. Gd neutron capture reaction includes both very short range (Auger electrons) and long range (IC electrons and gamma) products. In GdNCB the high-energetic gamma gives an almost flat absorbed dose delivery pattern, up to 4 mm around the stent. Dose distribution at the edges and inside the stent may prevent stent edge and in-stent restenosis. For GdNCT the absorbed dose from prompt gamma will dominate over the dose from IC and Auger electrons in an in vivo situation. The absorbed dose from IC electrons will enhance the total absorbed dose in the tumours and contribute to the cell killing.In paper IV a model for calculation of inter-cluster cross-fire radiation dose from β-emitting radionuclides in a breast cancer model was developed. GEANT4 was used for obtaining absorbed dose. The dose internally in cells binding the isotope (self-dose) increased with decreasing β-energy except for the radionuclides with substantial amounts of conversion electrons and Auger electrons. An effective therapy approach may be a combination of radionuclides where the high self-dose from nuclides with low β-energy should be combined with the inter-cell cluster cross-fire dose from high energy β-particles.In paper V MC simulations using correlated sampling together with importance sampling were used to calculate spectra perturbations in detector volumes caused by the detector silicon chip and its encapsulation. Penelope and EGSnrc were used and yielded similar results. The low energy part of the electron spectrum increased but to a less extent if the silicon detector was encapsulated in low z-materials.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

External Beam Radiotherapy
Gadolinium Neutron Capture Therapy
Gadolinium Neutron Capture Brachytherapy
Targeted Radionuclide therapy
Detector Response Modelling
Monte Carlo Simulation.
Radiological physics
Radiofysik

Publikations- och innehållstyp

vet (ämneskategori)
dok (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy