SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Blessborn Daniel)
 

Sökning: WFRF:(Blessborn Daniel) > Development and val...

Development and validation of a bioanalytical method using automated solid-phase extraction and LC-UV for the simultaneous determination of lumefantrine and its desbutyl metabolite in plasma

Lindegårdh, Niklas (författare)
Faculty of Tropical Medicine, Mahidol University, Bangkok 10400, Thailand; Nuffield Department of Clinical Medicine, Centre for Tropical Medicine, University of Oxford, Oxford, UK
Annerberg, A. (författare)
Faculty of Tropical Medicine, Mahidol University, Bangkok 10400, Thailand
Blessborn, Daniel (författare)
Högskolan Dalarna,Kemiteknik,Dalarna University College, S-781 88 Borlänge, Sweden
visa fler...
Bergqvist, Yngve (författare)
Högskolan Dalarna,Kemiteknik,Dalarna University College, S-781 88 Borlänge, Sweden
Day, N. (författare)
Faculty of Tropical Medicine, Mahidol University, Bangkok 10400, Thailand; Nuffield Department of Clinical Medicine, Centre for Tropical Medicine, University of Oxford, Oxford, UK
White, N.J. (författare)
Faculty of Tropical Medicine, Mahidol University, Bangkok 10400, Thailand; Nuffield Department of Clinical Medicine, Centre for Tropical Medicine, University of Oxford, Oxford, UK
visa färre...
 (creator_code:org_t)
Elsevier BV, 2005
2005
Engelska.
Ingår i: Journal of Pharmaceutical and Biomedical Analysis. - : Elsevier BV. - 0731-7085 .- 1873-264X. ; 37:5, s. 1081-1088
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • A bioanalytical method for the determination of lumefantrine (LF) and its metabolite desbutyl-lumefantrine (DLF) in plasma by solid-phase extraction (SPE) and liquid chromatography has been developed. Plasma proteins were precipitated with acetonitrile: acetic acid (99:1, v/v) containing a DLF analogue internal standard before being loaded onto a octylsilica (3 M Empore) SPE column. Two different DLF analogues were evaluated as internal standards. The compounds were analysed by liquid chromatography UV detection on a SB-CN (250 mm x 4.6 mm) column with a mobile phase containing acetonitrile-sodium phosphate buffer pH (2.0; 0.1 M) (55:45, v/v) and sodium perchlorate 0.05 M. Different SPE columns were evaluated during method development to optimise reproducibility and recovery for LF, DLF and the two different DLF analogues. The within-day precisions for LF were 6.6 and 2.1% at 0.042 and 8.02 μ g/mL, respectively, and for DLF 4.5 and 1.5% at 0.039 and 0.777 μ g/mL, respectively. The between-day precisions for LF were 12.0 and 2.9% at 0.042 and 8.02 μ g/mL, respectively, while for DLF 0.7 and 1.2% at 0.039 and 0.777 μ g/mL, respectively. The limit of quantification was 0.024 and 0.021 μ g/mL for LF and DLF, respectively. Different amounts of lipids in plasma did not affect the absolute recovery of LF or DLF.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Kemiteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Chemical Engineering (hsv//eng)

Nyckelord

antimalarial; lumefantrine; lipophilic; liquid chromatography; solid-phase extraction; stability; validation

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy