Acute evaluation of transthoracic impedance vectors using ICD leads.

  • Article/chapterEnglish2009

Publisher, publication year, extent ...

  • Wiley,2009

Numbers

  • LIBRIS-ID:oai:gup.ub.gu.se/107405
  • https://gup.ub.gu.se/publication/107405URI
  • https://doi.org/10.1111/j.1540-8159.2009.02363.xDOI

Supplementary language notes

  • Language:English

Part of subdatabase

Classification

  • Subject category:ref swepub-contenttype
  • Subject category:art swepub-publicationtype

Notes

  • BACKGROUND: Minute ventilation (MV) has been proven to be very useful in rate responsive pacing. The aim of this study was to evaluate the feasibility of using implantable cardioverter-defibrillator (ICD) leads as part of the MV detection system. METHODS: At implant in 10 patients, the transthoracic impedance was measured from tripolar ICD, tetrapolar ICD, and atrial lead vectors during normal, deep, and shallow voluntary respiration. MV and respiration rate (RespR) were simultaneously measured through a facemask with a pneumotachometer (Korr), and the correlations with impedance-based measurements were calculated. Air sensitivity was the change in impedance per change in respiratory tidal volume, ohms (Omega)/liter (L), and the signal-to-noise ratio (SNR) was the ratio of the respiratory and cardiac contraction components. RESULTS: The air sensitivity and SNR in tripolar ICD vector were 2.70 +/- 2.73 ohm/L and 2.19 +/- 1.31, respectively, and were not different from tetrapolar. The difference in RespR between tripolar ICD and Korr was 0.2 +/- 1.91 breaths/minute. The regressed correlation coefficient between impedance MV and Korr MV was 0.86 +/- 0.07 in tripolar ICD. CONCLUSIONS: The air sensitivity and SNR in tripolar and tetrapolar ICD lead vectors did not differ significantly and were in the range of the values in pacemaker leads currently used as MV sensors. The good correlations between impedance-based and Korr-based RespR and MV measurements imply that ICD leads may be used in MV sensor systems.

Subject headings and genre

  • Adult
  • Aged
  • Algorithms
  • Cardiography
  • Impedance
  • instrumentation
  • methods
  • Defibrillators
  • Implantable
  • Diagnosis
  • Computer-Assisted
  • instrumentation
  • methods
  • Electric Impedance
  • Electrodes
  • Implanted
  • Female
  • Humans
  • Male
  • Middle Aged
  • Reproducibility of Results
  • Respiratory Function Tests
  • instrumentation
  • methods
  • Respiratory Mechanics
  • Sensitivity and Specificity
  • Young Adult

Added entries (persons, corporate bodies, meetings, titles ...)

  • Daum, Douglas (author)
  • Kennergren, Charles,1948Gothenburg University,Göteborgs universitet,Institutionen för medicin, avdelningen för molekylär och klinisk medicin,Institute of Medicine, Department of Molecular and Clinical Medicine(Swepub:gu)xkench (author)
  • Ramuzat, Agnès (author)
  • Willems, Roger (author)
  • Edvardsson, Nils,1942Gothenburg University,Göteborgs universitet,Institutionen för medicin, avdelningen för molekylär och klinisk medicin,Institute of Medicine, Department of Molecular and Clinical Medicine(Swepub:gu)xedvni (author)
  • Göteborgs universitetInstitutionen för medicin, avdelningen för molekylär och klinisk medicin (creator_code:org_t)

Related titles

  • In:Pacing and clinical electrophysiology : PACE: Wiley32:6, s. 762-711540-81590147-8389

Internet link

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view