Search: WFRF:(Van Gelder I)
> (2005-2009) >
Implementation of d...
Implementation of device therapy (cardiac resynchronization therapy and implantable cardioverter defibrillator) for patients with heart failure in Europe: changes from 2004 to 2008
-
van Veldhuisen, D. J. (author)
-
Maass, A. H. (author)
-
Priori, S. G. (author)
-
show more...
-
Stolt, P. (author)
-
van Gelder, I. C. (author)
-
Dickstein, K. (author)
-
- Swedberg, Karl, 1944 (author)
- Gothenburg University,Göteborgs universitet,Institutionen för medicin, avdelningen för akut och kardiovaskulär medicin,Institute of Medicine, Department of Emergeny and Cardiovascular Medicine
-
show less...
-
(creator_code:org_t)
- 2009
- 2009
- English.
-
In: European Journal of Heart Failure. - 1879-0844. ; 11:12, s. 1143-51
- Related links:
-
https://gup.ub.gu.se...
Abstract
Subject headings
Close
- AIMS: Heart failure (HF) patients increasingly receive device therapy, either an implantable cardioverter defibrillator (ICD) or a biventricular pacemaker, also called cardiac resynchronization therapy (CRT), or a CRT device with an ICD (CRT-D). However, epidemiological data on the use of device therapy in Europe are limited. METHODS AND RESULTS: Data on implantation rates for conventional pacemakers, ICD, CRT, and CRT-D in 15 Western European countries were obtained from the Eucomed Registry for the 5-year period 2004-2008. Implantation of conventional pacemakers increased by 9% in Europe over the 5 years (reaching 907/million in 2008) and there were significant differences between countries. Implantable cardioverter defibrillator implantations increased by 75% from 80/million in 2004 to 140/million in 2008, and differences between countries were larger than those for conventional pacemakers. Implantation rates for CRT-P alone increased slightly from 2004 to 2006, but remained at 25/million thereafter in Europe overall. The total number of CRT implants (CRT-P and -D) markedly increased from 46/million in 2004 to 99/million in 2008 (115%), but this was mainly due to more CRT-D implants, i.e. an increase in the proportion of CRT-D (from 55% in 2004 to 75% in 2008). Implantation rates for ICD, CRT, and CRT-D remained markedly different throughout the study period between countries. CONCLUSION: Implantation rates of devices for HF, in particular ICD and CRT-D, have increased significantly between 2004 and 2008 in Europe, but there remain major differences between countries.
Subject headings
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Kardiologi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Cardiac and Cardiovascular Systems (hsv//eng)
Publication and Content Type
- ref (subject category)
- art (subject category)
Find in a library
To the university's database