SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Ritter A.)
 

Sökning: WFRF:(Ritter A.) > (2005-2009) > Conventional and de...

Conventional and dedicated atrial overdrive pacing for the prevention of paroxysmal atrial fibrillation: the AFTherapy study.

Camm, A J (författare)
Sulke, N (författare)
Edvardsson, Nils, 1942 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för medicin, avdelningen för molekylär och klinisk medicin,Institute of Medicine, Department of Molecular and Clinical Medicine
visa fler...
Ritter, P (författare)
Albers, B A (författare)
Ruiter, J H (författare)
Lewalter, T (författare)
Capucci, P A (författare)
Hoffmann, E (författare)
visa färre...
 (creator_code:org_t)
2007-10-03
2007
Engelska.
Ingår i: Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology. - : Oxford University Press (OUP). - 1532-2092. ; 9:12, s. 1110-8
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • AIMS: This investigation was conducted to determine the effectiveness of several conventional overdrive pacing modalities (single rate and rate responsive pacing at various lower rates) and of four dedicated preventive pacing algorithms in the suppression of paroxysmal atrial fibrillation (AF). METHOD AND RESULTS: In this multi-centre, randomized trial, 372 patients with drug-refractory paroxysmal AF were enrolled. Patients received a dual-chamber pacing device capable of delivering conventional pacing therapy as well as dedicated AF prevention pacing therapies and to record detailed AF-related diagnostics. The primary endpoint was AF burden, whereas secondary endpoints were time to first AF episode and averaged sinus rhythm duration. During a conventional pacing phase, patients were randomized to single rate or rate-responsive pacing with lower rates of either 70 or 85 min(-1) or to a control group with single rate pacing at 40 min(-1). In the subsequent preventive pacing phase, patients underwent pacing at a lower rate of 70 min(-1) with or without concomitant application of four preventive pacing algorithms. A substantial amount of data was excluded from the analysis because of atrial-sensing artefacts, identified in the device-captured diagnostics. In the conventional pacing phase, no significant differences were found between various lower rates and the control group receiving single rate pacing at 40 min(-1) or between single rate and rate-responsive pacing. Patients receiving preventive pacing with all four therapies enabled had a similar AF burden compared with patients treated with conventional pacing at 70 min(-1) (P = 0.47). CONCLUSIONS: The results do not demonstrate a significant effect of conventional atrial overdrive pacing or preventive pacing therapies. However, the observations provided important information for further consideration with respect to the design and conduct of future studies on the effect of atrial pacing therapies for the reduction of AF.

Nyckelord

Aged
Algorithms
Atrial Fibrillation
physiopathology
prevention & control
Cardiac Pacing
Artificial
methods
Female
Heart Atria
physiopathology
Heart Rate
physiology
Humans
Male
Middle Aged
Pacemaker
Artificial
Prospective Studies
Recurrence
prevention & control
Single-Blind Method
Treatment Outcome

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy